background image

Introduction

Introduction

TABLE CALL is an easy, smart wireless service bell with 
800 meter coverage in diameter. Users can manually 

program the table call system without using the PC. It 
helps restaurants to expedite their table turnover and 

service efficiency. 

The system capacity is up to 200 pcs table call TB-A06 
with 4 pcs receiver RE-300 that you may install from a 
small restaurant to bigger ones, which is very flexible. 

The high light of  this system are:

•  Monitor call function to assure high reliability

•  Wide coverage

•  Chargeable, long life span 

•  Manual programmable

TABLE Call is strongly recommended as simple solutions 

at below occasions: 

•  Restaurant 

•  Coffee Shop

•  Bars and cuisine

1

Содержание RE-300

Страница 1: ...Table Call System User Manual English...

Страница 2: ...Contents Introduction 1 Device Specification 2 Transmitter Service Call TB A06 2 Receiver RE 300 4 Operation Setting 6 Manual Programming 7 Trouble Shooting 9 Warning 10...

Страница 3: ...ervice efficiency The system capacity is up to 200 pcs table call TB A06 with 4 pcs receiver RE 300 that you may install from a small restaurant to bigger ones which is very flexible The high light of...

Страница 4: ...tion 2 LED indicator Under Charging Red LED on Battery low Red LED blinking when push the button under charging or in battery low Chargeable 10 pcs max at one stack The button Service call Blue LED li...

Страница 5: ...ntion at visual once it is pushed meanwhile sending alert page to the receiver in order to get service in shortest time It comes with Monitor call function to keep receiver aware of its availability C...

Страница 6: ...iver Device Specification 4 50 keys Blue A service on waiting Red Reminder after waiting time 1 3 minutes programmable Table call dis link Blue Red intercross blinking RX LED Blinking in Green when ge...

Страница 7: ...ers can lay it on reception desk or mounted on the wall It notifies the staff of which table is in need of service Capacity Up to 4 pcs in same group Key Spec 50 Key each one represents to one table m...

Страница 8: ...Paging Sensitivity dBm 122dBm 1200 Selectivity 25KHz 50dB Spurious Image Rejection 50dBm Frequency Stability 3ppm Receiver Type Synthesized Frequency Deviation 2 5KHz 4 5KHz Alert Tone SPL 80dB 10cm O...

Страница 9: ...5KHz Baud Rate bps 1200 Conducted Spurious Emission less 55dBc Frequency Stability 1ppm Operating power 3 6 4 5V Battery package 3 pcs Ni MH Rechageable battery 1 2V Standby 0 3mA Transmit 50 57mA Op...

Страница 10: ...eep on Blue light turn off Beep off Default value Beep on 3 Waiting Time Until hearing short beep you will see number 1 2 3 is on Then pressing number 1 2 or 3 again to set up waiting time After deter...

Страница 11: ...tton 1 21 Program pagers 1 Until you hear short beep and let go you will see that all blue lights turn on 2 Place SAP T programmer on the table call pressing its number then 50 until you hear long bee...

Страница 12: ...umber representing the first table call then press 50 until you hear long beeping For example Press NO 1 followed by 50 until you hear the long beeping You will see the LED indicator turn out to RED w...

Страница 13: ...interference might happen Each call are guaranteed to receive within 15 to 45 seconds 1 If the button without receiving the message please manually dismiss the lights on the RE 300 and clear the ligh...

Страница 14: ...12 RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Warning...

Страница 15: ...Make sure to read this manual before using the machine Please keep it in hand for future reference 765 00009 0...

Отзывы: