Caramatic BasicControl
Artikel-Nr. 71 392 50
19 / 24
Installation on the two-cylinder system Caramatic BasicTwo
•
Fit the medium pressure hose assembly of
the two-cylinder system Caramatic
BasicTwo with the connection M G 3/8 lh
nut to the T-piece , tightening torque
15Nm.
•
Connect the inlet connector of the
changeover regulator to the gas cylinder
valve in such a way that the signal
transmitter is at the top.
•
Only connect by hand, do not use tools!
(Left-hand thread!).
•
Tighten the connections firmly.
•
CHECK FOR LEAKS at the connections (see assembly and operating manual
“Two-cylinder system Caramatic BasicTwo” part no. 02 018 51).
ELECTRIC CONNECTION
In the case of systems in connection with areas where there is a risk of explosion,
compliance is required with the appropriately valid national regulations and installation
regulations!
In the case of repair work or changes to explosion-proof apparatus, compliance is
required with the national regulations!
In the case of repair work and maintenance,
original spare parts
may only be used.
Changeover regulator of the two-
cylinder system Caramatic BasicTwo
Signal transmitter for remote display
2-part (ring and cap)
T-piece with connection cable
between pressure and reed sensor
Connection cable transmitter for
remote display from pressure
sensor and reed sensor
Information and control unit (control panel)
10-pin connector on cable +
Connection cable for connection
Connection cable for connection to the
12V - power supply of the leisure vehicle
Cover socket
Connection between the 3-pin connector
and the 3-pin socket , Extension possible
(see LIST OF ACCESSORIES)
According to EN 1648-1 or EN 1648-2 chapter 6.1 Positive conductor
protection, a fuse (min. 1A to max. 3A) must be fitted at maximum 1m distance from the 12V
leisure vehicle supply so as not to overload the connection cable.