GOJO LTX-7
™
AND LTX-12
™
DISPENSER
INSTALLATION INSTRUCTIONS
These instructions apply to GOJO
®
, PURELL
®
, PROVON
®
and MICRELL
®
brand LTX-7 and LTX-12 dispensers.
Please read all instructions carefully before installing and using the dispenser.
Insert a flat blade screwdriver into
the slots on the refill collar and
twist to separate the collar from
the refill. Unscrew the pump from
the bottle and discard.
1.
Bottle is recyclable.
2.
Open dispenser by by pushing
on one (or both) of the dual
side latches.
1.
Wait 24 hours before loading
refill.
5.
Remove cap from refill pump. You
will notice a small knob (E-key)
protruding from the white pump
collar –
DO NOT REMOVE THIS
E-KEY
as its removal will prevent
the refill from dispensing. Push
refill with E-key facing the back
plate, into pump house.
7.
When installing above a
countertop, be sure at least 6"
clearance is provided.
2.
6”
15.24 cm
Clean installation surface with
an alcohol pad. Allow surface to
dry for 60 seconds. Peel paper
off installation tape.
3.
Tape Installation (Steps 3, 4 and 5)
Press firmly on back plate for 10
seconds. For maximum adhesion,
do not load refill for 24 hours.
4.
Close dispenser. Battery indicator
light will initially alternate
blinking red and green. After a
few moments, indicator light will
consistently blink green when
the refill is properly loaded.
9.
Using back plate as a template,
press a pencil through the
installation tape to mark holes.
Mark and drill holes. Install with
#10 x 1” anchors and type A
#10 x 1” screws.
6.
Install 4 fresh D-cell alkaline
batteries according to diagram
shown on dispenser.
8.
Recycling
Fastener Installation
(Step 6)
Do not install in locations where dispenser may be exposed to wet environments, such as showers or areas where walls are
washed down. Installer can complete installation using tape, fastners, or both to secure dispensing system to the wall.
Содержание LTX-7