Chapter VI. Placement 

The environment of the frequency converter being placed has direct affect to converter's function and lifetime, 

the environment should follow the conditions: 

Moving: 

 

Please shut down and disconnect all wirings before moving the frequency converter. 

 

Do not move the frequency converter upside down. 

 

Handle the frequency converter with care in moving to avoid collision. 

Placement 

 

Do not put the frequency converter on uneven or inclined place. 

 

Avoid direct sunlight, rain or humid place 

 

Keep it away from fire and high temperature place to prevent overheating. 

 

Avoid oil mist, salt, corrosive gases erosion. 

 

Avoid dust, cotton and small metal objects intrusion. 

 

Keep the frequency converter in a well-ventilated place, keep the frequency converter's back away from the 

wall at least 10cm to ensure sufficient ventilation. 

 

Operating temperature 0 - 40

, humidity 0 - 90% (non-condensing).   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание HZ-60-1101

Страница 1: ...Frequency Converter Programmable 50Hz 60Hz 400Hz Frequency Converter Solutions for Converting 110V 60Hz to 220V 50Hz 120V 60Hz to 240V 50Hz 230V 50Hz to 110V 60Hz etc Power Capacity from 500 VA to 50...

Страница 2: ...Operation Panel and Functions 6 V Operating Guide 7 Menu Selection Parameter Setting Procedure Specific Operation Settings VI Placement 8 VII Installation 9 12 Wiring Precautions Wiring Diagram Wire D...

Страница 3: ...stallations according to different capacities and voltage levels choose an appropriate configuration and wire diameter Do not overload the frequency converter and wire to prevent the electric shock or...

Страница 4: ...dule design to reduce circuit complexity enhance frequency converter stability and reduce power consumption And the isolation transformers completely isolate the mains and the loads in order to improv...

Страница 5: ...rt circuit current limitation High accuracy digital key input voltage frequency Fault code records easy for troubleshooting Applications Laboratory standard power supply Air compressor testing Monitor...

Страница 6: ...panel Input Switch SET set voltage and frequency values in standby mode OK button to confirm W PF power and power factor switch Up Down adjust voltage Left Right adjust frequency M1 M4 shortcut of pa...

Страница 7: ...normality 5 Program Settings press up down buttons to switch terminate parameter sets elect parameter sets and running mode press left right buttons to change the sub options of terminate parameter se...

Страница 8: ...y converter with care in moving to avoid collision Placement Do not put the frequency converter on uneven or inclined place Avoid direct sunlight rain or humid place Keep it away from fire and high te...

Страница 9: ...er to electrician wiring regulations or following the wire diameter reference table Avoid the switch of the frequency converter share with other appliances Use O type wiring terminals make sure it s w...

Страница 10: ...0V 136 4A 125 0mm2 3 4W 220V 380V 3 3W 380V 3 Model Input Output GoHz Max I P Current Protection Breaker Power Wire Max O P Current Power Wire 3306 6KVA 12 6A 30 0A 2 0mm2 110V 18 2A 220V 9 1A 3 5mm2...

Страница 11: ...wire systems are 100V 110V 115V 120V 127V 132V 139V 220V 230V 240V 254V 277V If the voltage between Ground Wire and Neutral Wire is higher than 5V or the equipment has specific requirement please find...

Страница 12: ...unding for the best 6 Ground Types Item Applications Resistance values 1 Low voltage power supply system or high voltage electrical equipment of three phase four wire multi grounded systems grounding...

Страница 13: ...Display Voltage Current Frequency Power Power Factor Voltage Regulation 0 10 Load Regulation 0 50 Total Harmonic Distortion THD 1 Pure resistive loads Frequency Stability 0 01 Voltage Resolution 0 1V...

Страница 14: ...N to reboot 2 Make sure the loads are within the frequency converter s capacity No output voltage 1 Is the fuse burn down or not 2 Is it overloaded 1 Check the fuse and replace the fuse with same spec...

Страница 15: ...s windy and dusty pay more attention to make the frequency converter clean or do more frequent maintenances Maintenances Turn off the power switch Clean inner dusts Wipe the cabinet cover and venting...

Отзывы: