- 19 -
Doku VARIOMAX_engl_06 12
June. 2012
Goch GmbH & Co. KG
13. Nozzle Pressures Table (Manifold pressures)
VARIOMAX One- or Two Stage High Intensity Heater
Type
Nominal
Input
Load
Gas Type
Min. Supply
System
Pressure
Manifold
Pressure
Nozzle
Orifice ø
Air Plate ø
kW
mbar
mbar
mm
mm
VARIOMAX 06
3 - 6
Nat. gas G20
20
19,0
2 x 1,30
without
VARIOMAX 12
6 - 12 Nat. gas G20
20
18,8
2 x 1,85
38
VARIOMAX 06
3 - 6
Nat. gas G25
20
19,0
2 x 1,45
25
VARIOMAX 12
6 - 12 Nat. gas G25
20
18,6
2 x 2,00
35
VARIOMAX 06
3 - 6
Propane G31
60
50
2 x 0,80
22
VARIOMAX 12
6 - 12 Propane G31
60
50
2 x 1,10
35
14. Technical Data
Type
Gas Consumption (Half Load - Full Load)
Dimensions
G20
G25
G31
A
B
Wt.
m³/h
m³/h
kg/h
mm
mm
kg
VARIOMAX 06
0,30 - 0,60
0,35 - 0,70
0,23 - 0,47
1408
438
7
VARIOMAX 12
0,60 - 1,20
0,70 - 1,40
0,47 - 0,93
1778
807
17,5
Nat. Gas G20 ;
Hi = 9,97 kWh/m³ ;
Ws = 14,89 kWh/m³
Nat. Gas G25 ;
Hi = 8,57 kWh/m³ ;
Ws = 12,15 kWh/m³
Propane G31 ;
Hi = 12,87 kWh/kg ;
Ws = 22,55 kWh/m³
Lower Heating Value Hi und Wobbe Index Ws bei 0° C und 1013 mbar
346
B
625
A
263