Hardware
3-8
PXI/ PCI 61xx – User Manual
PXI 61xx
boards provide a 1Gbit Ethernet interface and a PXI interface.
Both interfaces can be used for the communication of the unit with the
host PC.
In case of using the
Ethernet
interface, the boards can be controlled via
the
default IP Address
192.168.1.62
,
Port 5134
, which can be changed if
In principle, there are two ways for this:
♦
HardwareExplorer: Select the device,
under
Device
set the required
IP Address
;
the new
IP Address
is effective after restart
♦
G API Command
G_Common_Ethernet_IpAddress_Set
;
the new
IP Address
is effective after restart
PXI 61xx:
A
PXI 61xx
board can read out this geographical slot address.
PXI
racks do have an own geographical slot addressing of
the backplane.
Numbering starts with
1
and can be seen at the cover’s front side.
Mount always an embedded controller or an MXI card at slot
1
.
3.3.2
Addressing