Step 3: Connect Fill Hoses

Water Supply

Water supply faucets must fit standard 3/4 inch 

(19.1 mm) female garden hose couplings. DO NOT 

USE SLIP-ON OR CLAMP-ON CONNECTIONS.
Water supply faucets should be readily accessible to 

permit turning them off when washer is not being 

used.
Recommended cold water temperature is 50

to 

75

o

Fahrenheit (10

o

 to 24

o

 Celsius). Recommended 

maximum hot water temperature is 125

o

 Fahrenheit 

(51

o

 Celsius). Warm water is a mixture of hot and cold 

water. Warm water temperature is dependent upon 

water temperature and pressure of both the hot and 

cold water supply lines.

Water pressure must be a minimum of 20 to a 

maximum of 120 pounds per square inch (138 to 

827 kPa) static pressure measured at the faucet.

NOTE: Water pressure under 20 pounds per 

square inch (138 kPa) will cause an extended fill 

time in the washer.

Turn on the water faucets and flush the lines for 

approximately two minutes to remove any foreign 

material that could clog the screens in the water 

mixing valve.

NOTE: When installing in newly constructed or 

renovated buildings, it is very important to flush 

the lines since build-up may have occurred during 

construction.

Connecting Hoses

Remove the two plain rubber washers and two filter 

screens from the accessories bag. Install them into 

each end of the fill hoses as shown in 

Figure 5

. The 

screen must be facing outward.
Screw hose couplings with the filter screens onto the 

water faucets until they are finger-tight. Then, using a 

pliers, screw approximately 1/4 turn. Use the red 

color-coded hose for the hot water connection and the 

blue color-coded hose for the cold water connection.
Screw hose couplings from other end of hoses onto the 

water mixing valve until they are finger-tight. Then, 

using a pliers, screw approximately 1/4 turn. Refer to 

Figure 6

Make sure the red color-coded hose from the 

hot water faucet goes to the water mixing valve 

marked “H” and the blue color-coded hose from the 

cold faucet goes to the valve marked “C”.

 

IMPORTANT: Do not cross thread or overtighten 

couplings. This will cause them to leak.

Turn water on and check for leaks. If leaks are found, 

turn off the water, unscrew hoses and reinstall them 

until there are no leaks. 

IMPORTANT: Turn off water supply whenever 

there will be an extended period of non-use.

Mixing Valve Flow Rates (Gallons per Minute)

Hot

Cold

Warm 

(40% Hot)

35 psi

2.4

4.5

7.15

55 psi

3.5

6.2

9.2

Table 1 

Under certain conditions, hydrogen gas 

may be produced in a hot water system 

that has not been used for two weeks or 

more. HYDROGEN GAS IS EXPLOSIVE. If 

the hot water system has not been used 

for such a period and before using the 

washer, turn on all hot water faucets and 

let the water flow from each for several 

minutes. This will release any 

accumulated hydrogen gas. The gas is 

flammable. Do not smoke or use an open 

flame during this time.

W029

WARNING

To prevent personal injury, avoid contact 

with inlet water temperatures higher than 

125

°

 Fahrenheit (51

°

 Celsius) and hot 

surfaces.

W748

WARNING

www.goedekers.com

Содержание Speed Queen awn432sp

Страница 1: ...nges ownership this manual must accompany machine www speedqueen com Installation Instructions for Topload Washers Washer Dimensions 2 Before You Start 2 Installation 3 Installer Checklist Back Cover Date Purchased ________________ Model Number ________________ Serial Number _________________ Part No 201471R3 April 2012 Inside www goedekers com ...

Страница 2: ...tion Instructions User s Guide Warranty Bond NOTE If the washer is delivered on a cold day below freezing or is stored in an unheated room or area during the cold months do not attempt to operate it until the washer has had a chance to warm up NOTE Install dryer before washer This allows room for attaching exhaust duct With leveling legs turned into base TLW2075N Figure 1 28 in 71 1 cm 53 in 134 6...

Страница 3: ...or sides when moving Save the shipping brace and plug They must be reinstalled whenever washer is moved or transported to a new location This will prevent damage to the washer Refer to the User s Guide for instructions on reinstalling the shipping materials Step 2 Wipe Out Inside of Washtub Prior to first wash use an all purpose cleaner or a detergent and water solution and a damp cloth to remove ...

Страница 4: ...Screw hose couplings with the filter screens onto the water faucets until they are finger tight Then using a pliers screw approximately 1 4 turn Use the red color coded hose for the hot water connection and the blue color coded hose for the cold water connection Screw hose couplings from other end of hoses onto the water mixing valve until they are finger tight Then using a pliers screw approximat...

Страница 5: ... a minimum of 1 1 4 inch 32 cm outside diameter drain hose Standpipe Installation Place the adapter into the standpipe The recommended height for the standpipe is 36 inches 91 44 cm Standpipes higher than 4 feet 122 cm are not recommended Remove the beaded strap from accessories bag and place around standpipe and drain hose approximately 12 inches 30 cm down from the top of pipe and tighten strap ...

Страница 6: ...e beaded strap from accessories bag Refer to Figure 9 NOTE End of drain hose must be below height of cabinet top Laundry Tub Installation For this type of installation the drain hose MUST be secured to the stationary tub to prevent hose from disloding during use Refer to Figure 10 Use the beaded strap supplied in accessories bag to secure hose We recommend leaving the standpipe adapter on the drai...

Страница 7: ...ilt washer back to access the front leveling legs Loosen the locknuts and adjust legs by screwing into or out of washer base Once adjusted tilt the washer forward on front legs and lower back down into position to set the rear self leveling legs Make sure that the washer does not rock When washer is level and does not rock tighten locknuts securely against bottom of washer base If these locknuts a...

Страница 8: ...to a polarized three slot effectively grounded receptacle rated 110 120 Volts AC alternating current 15 Amps Refer to Figure 13 to determine correct polarity of the wall receptacle DRY2022N 1 L1 2 Ground 3 Neutral Side 4 Round Grounding Prong 5 Neutral Figure 13 1 2 3 4 5 Standard 120 Volt 60 Hertz 3 Wire Effectively Grounded Circuit 0 V A C 120 12 V A C 120 12 V A C To reduce the risk of fire ele...

Страница 9: ...problem NOTE The wiring diagram is located in the control hood Step 7 Add Water to the Washer To prevent damage to pump do not run washer before adding at least one quart water to the tub If the washer is run before any water is added the pump seal may overheat causing the pump to leak Once installed the water retained in the drain system from the previous cycle will provide sufficient cooling to ...

Страница 10: ...hould stop agitating and spinning when lid is opened Step 9 Check Installation Refer to Installer Checklist on the back cover of this manual and make sure that washer is installed correctly Run washer through one complete cycle to make sure it is operating properly W376I Figure 15 W376IE0A www goedekers com ...

Страница 11: ...www goedekers com ...

Страница 12: ...of Washtub 2 CHECK TLW2009N TLW2009N Connect Fill Hoses TLW1988N HOT COLD C H 3 CHECK TLW1988N Filter Screens Cold Valve Connection Hot Valve Connection Plain Washers Red Blue Connect Drain Hose to Drain Receptacle 4 CHECK W315IE0A W315IE0A W316I Position and Level the Washer 5 CHECK LEVEL D255I D255I W316I 6 CHECK D254I Plug in the Washer D254I 7 CHECK W391I Add Water to the Washer W391I W376IE0A...

Отзывы: