Installation, Operation and Maintenance Manual
CD, HL & NC Ranges of Dri-Prime
®
Pumps
26
95-0019-0000 Iss 11
8.6 Bearing Bracket & Motor Adaptor Dismantling
8.6.1
Preparation for dismantling
Use suitable lifting gear to remove the pump assembly from the driver. It may be convenient to remove the air compressor
assembly or vacuum pump (if fitted) before doing so. See Section 8.11.1 for details.
Support the pump unit in a suitable manner before commencing further strip down.
Carry out the instructions for seal removal (Section 0) before commencing any work detailed in this section.
8.6.2 Dismantling
Pump types
CD75/ CD80D/ CD80M/ CD100M/ CD103M/ CD140M/ CD150M/ CD160M/ CD180M/ CD200M/ CD225/
CD250M
NC80/ NC100/ NC150
1)
CD160M, CD180M
Undo the fasteners holding the seal-housing adaptor to the bearing housing and remove the seal housing adaptor.
Undo the fasteners holding the SAE adaptor to the bearing housing and remove the SAE adaptor.
2)
Unscrew the drive end bearing cover fasteners and remove the drive end bearing cover.
3)
CD75, CD80D, CD80M & CD160M
motor adaptor units.
Release the tab washer and remove the bearing locknut.
4)
Extract the shaft and bearing assembly.
5)
Remove pump end bearing cover on bearing bracket units where the cover is retained by screws.
CD100, CD103M,
CD150M, CD250M, NC80, NC100, & NC150
motor adaptor units have their pump end bearing cover retained by a
circlip. Do not remove the clip, cover or pump end outer bearing race unless required for cleaning purposes or because
of damage.
6)
If necessary, remove the bearing inner races from the shaft.
7)
Inspect all parts for damage or wear and replace as necessary. All lip seals and O-rings
must
be replaced.
Pump types
HL80/ HL100M/ HL110M/ HL125M/ HL150M/ HL200M
1)
HL80
Undo and remove the nuts and spring washers from the studs holding the pump body to the bearing bracket or motor
adaptor.
Undo and remove the pump body holding down bolts (if fitted). Remove the pump body.
Pull the collar and tolerance ring off the pump end of the shaft.
HL100M, HL125MS, HL150M, HL150MHD, HL110M & HL200M
Release the nuts on the bolts holding the seal housing adaptor to the bearing bracket and remove the fasteners.
Remove the adaptor.
For pumps other than the HL110M or HL200M this will include the shaft lip seal.
For the HL110M or HL200M this will include the rear mechanical seal seat if it has not already been removed.
2)
Unscrew both bearing cover fasteners and remove the bearing covers.
3)
HL100M, HL125MS, HL150M, HL150MHD, HL110M & HL200M
Release the pump end tab washer, lock the shaft against rotation and remove the bearing locknut.
4)
Extract the shaft and bearing assembly from the drive end, leaving the pump end outer bearing race in place.
5)
HL80
Motor adaptor units have their pump end bearing cover retained by a circlip. Do not remove the clip, cover or pump end
outer bearing race unless required for cleaning purposes or because of damage.
6)
Remove pump end bearing cover.
7)
If necessary, remove the bearing inner races from the shaft.
8)
Inspect all parts for damage or wear and replace as necessary. All lip seals and O-rings
must