Installation, Operation and Maintenance Manual
CD, HL & NC Ranges of Dri-Prime
®
Pumps
12
95-0019-0000 Iss 11
8 MAINTENANCE
8.1 Bearings
All CD, HL & NC range pump shafts are supported from two bearing positions. The types of bearings and configurations
vary across the ranges.
8.1.1 Re-greasing
procedure
Grease specification and greasing interval: - Check every 250 hours and recharge if necessary. Do not overgrease. See
Technical Data section for grease types.
Grease nipple positions: - See Figure 14
Clean both the grease nipple and the grease gun nozzle thoroughly before application. Two or three strokes of a hand held
grease gun per grease nipple are sufficient. Overfilling the bearings with grease can be as harmful as under lubrication.
Compaction of grease results in it being churned by the rolling action of the bearings which leads to overheating, breakdown
of the lubricant and ultimately bearing failure.
CAUTION.
Failure to re-grease the bearings correctly with the correct type of grease at suitable intervals could result in
premature bearing failure.
Remove any excess grease from the unit, particularly in the area of any drive belt. Grease on the drive belt will shorten its
life and lead to premature failure.
Figure 14 Grease nipple positions
CD80-02
Pump
body
Adaptor
CD80-05
Pump
HL100-07
HL200-01
Grease
relief
valves
Grease nipple
accessed through
adaptor
CD100-03
Adaptor
Pump
CD225-03
Adaptor
Pump
HL250-04
Adaptor
Pump
Grease
nipples