background image

-  22  -

Long Press the <

SYNC

1

button for 2 seconds so that  
<     > is blinking. Turn the 
Select Dial until the <        > is 
displayed on the LCD panel, 
which means the slave unit. 

Slave Unit Setting

Press the <

SLAVE

> Button to 

1

c h o o s e   t h e   g r o u p   f r o m  

M/A/B/C

.  Then,  press  the  < 

MODE

  >  Button  so  that  the 

master unit can work in 

OFF / 

TTL  /  M 

flash  mode.  Choose 

one  of  them  as  the  flash 
mode of master unit.

4. Setting the Communication Channel

If there are other wireless flash systems nearby, you can change the 
channel  IDs  to  prevent  signal  interference.  The  channel  IDs  of  the 
master unit and the slave unit(s) must be set to the same.

Long press the <

SLAVE

1

Button for 2 seconds until the 
channel IDs is blinking. Turn 
the Select Dial to choose a 
channel ID from 1 to 16.

Press the <

SET

> button to 

2

confirm.

2. Setting Group Unit’s Flash Mode

Press the <

MODE

> Button for 

2

2 seconds to switch to Multi 
mode.

Autoflash Shooting with One Slave Unit

6. TTL: Fully Automatic Wireless Flash Shooting

Master Unit Setting

1

● 

Attach a TT350P camera 

flash on the camera and set it 
as the master unit.  (Page 36)

          ● 

M/A/B/C

 can be set as 

             

TTL

 mode independently.

Slave Unit Setting

2

● 

Set the TT350P that to be  

   controlled as the wireless 

  

   slave unit. (Page 37)

    

     

● The slave unit can be set 

            

as

 A/B/C

Check the communication 

3

channel

● 

If the master unit and 

   slave unit(s) are set to a 
   different channel, set them 
   to the same channel. 
   (Page 37)

Position the camera and 

4

flashes

 Position the camera and 

   flashes as the picture 
   shows. (Page 40)

Check the flash operation

5

● 

Press the master unit’s  

   Test Button<    >

.

          ●

 Then, the slave unit will 

             fire. If not, adjust the slave 
             unit’s angle toward the 
             master unit and distance 
             from the master unit.

The slave unit might be out of order or fire an unwanted flash 
due to the nearby wifi routers or other 2.4G equipments. If in 
this case, please adjust the flash’s channel or turn off the 2.4G 
equipments.

-  37  -

-  38  -

ZOOM

SYNC

SLAVE

SET

ZOOM

SYNC

SLAVE

SET

ZOOM

SYNC

SLAVE

SET

MODE

ZOOM

SYNC

SLAVE

SET

3. Master Unit's Flash OFF

When the flash attach to camera, 

1

enter the external speedlite 
control on the camera menu.

Turn off the master control flash 

2

on the camera. The <     > icon 
will blink on the TT350P panel, 
and the flash master control unit 
is disabled. Select turn on to 
cancel the master control unit 
disabled.

ZOOM

SYNC

SLAVE

SET

MODE

ZOOM

SYNC

SLAVE

SET

5. Wireless ID Settings

Change the wireless channels and wireless ID to avoid interference 
for it can only be triggered after the wireless IDs and channels of the 
master unit and the slave unit are set to the same. 

Press the <MENU> button to enter C.Fn ID. Press the <SET> button 
to choose OFF channel expansion shutdown, and choose any figure 
from 01 to 99. 

Содержание Thinklite TT350P

Страница 1: ...in order to ensure your safety and the proper operation of this product Keep for future reference 705 TT350P 00 Made in China Add A4 Building A4 Xinhe Huafa Industrial Zone Fuzhou RD West Fuyong Town...

Страница 2: ...in or in damp conditions Do not disassemble Should repairs become necessary this product must be sent to an authorized maintenance center Keep out of reach of children Stop using this product if it br...

Страница 3: ...ooting with Manual Flash Other Applications Auto Focus Assist Beam Bounce Flash Creating a Catchlight ZOOM Setting the Flash Coverage and Using the Wide Panel Low Battery Indicator C Fn Setting Custom...

Страница 4: ...long press for 2 seconds 18 Wireless Selection Button reusable button long press for 2 seconds 19 GR CH Group Channel Button reusable button in wireless mode 20 Select Dial 21 SET Set Button Control...

Страница 5: ...ode after a certain period adjustable 60 minutes by default of idle use Pressing any flash button will wake it up Disabling Auto Power Off function is recommended when the flash is used off camera C F...

Страница 6: ...t amount In high speed sync mode the adjustable flash range is 1 16 1 1 Figures displayed when reducing flash output level Figures displayed when increasing flash output level 1 4 1 2 1 1 1 1 0 3 1 2...

Страница 7: ...tter closes or the battery is exhausted The number of flashes will be limited as shown by the following table Maximum Stroboscopic Flashes 1 4 1 8 1 16 1 32 1 64 1 128 1 6 14 30 60 90 90 2 3 14 30 60...

Страница 8: ...Check the communication 3 channel If the master unit and slave unit s are set to a different channel set them to the same channel Page 37 Position the camera and 4 flashes Position the camera and flas...

Страница 9: ...30m Use the supplied mini stand to position the slave unit Before shooting perform a test flash and test shooting The transmission distance might be shorter depending on the conditions such as positi...

Страница 10: ...he wide panel back in 3 Push in only the wide panel Follow the same procedures as for bounce flash Point the flash head straight ahead and then upward by 90 The catchlight will not appear if you swing...

Страница 11: ...e of about 10 minutes and the flash unit will then return to normal When the over temperature protection is started is shown on the LCD panel Number of flashes that will activate over temperature prot...

Страница 12: ...00 seconds first curtain sync and second curtain sync attaching on the camera Provided up to 90 times 90Hz Model Compatible Cameras Guide No 1 1 output 105mm Flash Coverage Flash Duration t0 1 Exposur...

Страница 13: ...Pull the wide panel out to extend the flash coverage Troubleshooting Compatible Camera Models Shut down the device immediately should abnormal operation be detected Avoid sudden impacts and the produ...

Отзывы: