LIGHTING AND REGULATION 

 

Use the unit on low fire for the first 2 – 3 days to allow the parts of the unit to expand naturally. 

 

Use the operating tool or glove when opening the door. 

 

Do not worry if during the first lighting fumes are emitted from the unit, this is due to oils used during 
the manufacturing process and the curing of the paint. The smell of fumes will dissipate after the unit 
has been used a few times. 

 

To  light  the  unit  –  open  the  door  and  insert  smaller  pieces  of  wood  –  light  the  unit  –  fill  slowly  and 
moderately, while leaving the air intake completely open. 

 

To  assist  with  the  initial  lighting  of  the  unit,  it  is  possible  to  leave  the  door  slightly  open  for  a  few 
minutes. 

 

Once the fire is well lit, load the necessary amount of wood and adjust the air intake accordingly. 

 

REMOVAL OF ASHES 

 

Remove the ash pan at least every 2-3 days or every 8 hours. 

 

Never let the ashes build up in the ash pan until they touch the grate. This would stop the grate from 
cooling down and would cause the grate to rapidly deteriorate. 

 

SWEEPING OF THE CHIMNEY 

 

It is advisable to sweep and inspect your chimney at least once a year. Clean the unit and check the 
door seals. Inspect the internal flue and remove and clean the T-piece bowl if it has been utilized. Use 
the Godin chimney cleaner Ref: 0008 at the beginning and end of each season. Clean the internal part 
of the appliance thoroughly without forgetting the top of the baffle plates. 

 

It is important never to attempt to clean the glass of the unit while it is still hot. 

 

THE IMPORTANCE OF FUEL 

 
Godin  heaters  have  a  thermal  output  close  to  70%  efficiency.  Never  the  less,  you  must  not  forget  that  its 
heating is only as efficient as the energy included in the materials used. 
 
If the stoves heat performance is unsatisfactory to you, it could be one of two things: 

-

 

Either the fuel quantity is not enough or 

-

 

The fuel burnt has a low energy output 

Only burn dry wood that has been dried for at least 2 -3 years. Humidity in the wood goes from 15% to 50% 
(for wet wood). Normally all woods have the same calorific power for the same weight. Hard wood is more 
suitable as it has a higher density and often has less humidity. Using wet wood can damage the chimney and 
cause fires in the chimney flue. 
 

REPLACEMENT OF PARTS 

If you need to replace some parts, please contact your supplier or one of our approved dealers, give him the 
product date as displayed in your warranty slip, or on your appliance’s name plate at the rear of the unit. Our 
dealers are in possession of all spare parts and technical datas about our products, and will provide you with 
the spare parts you need and any maintenance intervention within the scope of the professional competence. 
 
 

Содержание 362105

Страница 1: ...models large panoramic heat resistance vitro ceramic glass heat resistance to 750 deg C Dimensions of loading opening cm 46x30 46x30 46x24 All mentioned models cast iron firebox All mentioned models manual regulation Weight 120kg 116kg 106kg Heat output 13kW 13kW 9kW Heating Volume 200 500m3 200 500m3 130 330m3 All mentioned models rate of normal combustion depending on fuel properties 3hrs All me...

Страница 2: ...appropriate flue outlet connection to a chimney which must guarantee sufficient draught flow capacity is of the utmost importance It is of course preferable that this appliance be installed by a professional which knows of all relevant codes of practice and safety regulations and who can guarantee a flawless installation Line drawing for the Ecoval Ref 362105 ...

Страница 3: ...3 P a g e Linedrawings for Le Cerval Ref 364101 Linedrawing for Le Cervalou Ref 364112 ...

Страница 4: ...d must be very open angled The draught must range between 1 5mm WG and 2mm WG when burning normally and must drop at 0 5mm WG roughly when burning slowly If the draught is too high a damper should be fitted If the draught is insufficient check if the characteristics of the chimney comply with those prescribed in this paragraph If the cross section of the fireplace is too large the volume to be hea...

Страница 5: ...e right hand side need to be a minimum of 30cm from the unit and made of non flammable materials The rear wall must not be of flammable materials If the rear wall is of a flammable material it must be protected sufficiently and effectively GENERAL INFORMATION When operating the unit do not open the door by hand use the operating tool supplied The units are designed to be burnt with the door in the...

Страница 6: ...ing low Do not open the door of the unit if it s running on high or if large flames are visible If opening the door when the flames are visibly high there is a risk they could leap outside the fire cavity Always open the door gently allowing the draught to stabilize and to avoid a down draught GENERAL PRINCIPLES OF CONNECTION FOR REAR AND TOP FLUE OUTLETS WHERE POSSIBLE ...

Страница 7: ...een utilized Use the Godin chimney cleaner Ref 0008 at the beginning and end of each season Clean the internal part of the appliance thoroughly without forgetting the top of the baffle plates It is important never to attempt to clean the glass of the unit while it is still hot THE IMPORTANCE OF FUEL Godin heaters have a thermal output close to 70 efficiency Never the less you must not forget that ...

Страница 8: ...y a competent professional acting under his own responsibility In the interest of constant product improvement GODIN SA reserves the right to change specifications without notice These instructions will help you obtain the most effective performance from you appliance under normal operating conditions if any problems concerning your appliance should arise do not hesitate to contact your supplier w...

Страница 9: ...9 P a g e ...

Страница 10: ...10 P a g e ...

Страница 11: ...11 P a g e ...

Страница 12: ...rts Some parts have a longer guarantee 3 years for cast iron or steel heating body of our boilers for central heating Wood burning Inserts and closed fireboxes running with wood have a 5 year warranty only the heating body parts in direct contact with high temperatures and undergoing wear and tear described above have 1 year guarantee Only the parts s that are deemed to have failed will be covered...

Страница 13: ...le for any installation assembly dismantling costs and consequential removal of the appliance Consequently Godin SA cannot be held responsible for any materials loss or human accidents being a result of incorrect installation non observing the legal provisions and regulations for example lack of ground connection incorrect draft of the chimney etc In order to constantly improve our products we res...

Отзывы: