13
12
the vehicle module or component can work normally, it means that there is a problem
with the vehicle's positive power supply circuit for this module.
Note: If the pressing of the positive output causes a trip and open circuit, it
means that the tool has been overloaded.
The following reasons may explain it: The probe is directly in contact with GND or
the component you are testing is short-circuited.
If the positive output of the product is delivered to a high-current module or
component, it will cause the product to trip. At this time, reconnect the device and it
will function normally.
4.
)
Test of Modules Installed in the Vehicles
This product can test modules installed in the vehicles. Engineers can judge the
performance of components based on their own experience and technology. Let the
probe output positive or negative electricity to achieve the purpose of testing a single
component.
Use this product to perform activation tests on the modules or components
installed in the vehicle. Find the positive circuit and connect the probe to the positive
electrode of the circuit. If the foggy bi-color LED
light should be green, the buzzer
emits a low-frequency sound, it means that the GND connection of the module or
component is normal. Press the Godiag GT103 Mini Pirt Electric Circuit Tester power
output function switch forward, positive electricity will be output to the probe circuit. If