8.3
Label settings (1-Label Mode)
I.
Selecting 1-Label mode:
-Hold
the “ ”
button to enter the AP16-F menu
-Select the program you want to use or edit with the and buttons
-hold
the “M” button to
open the settings
-Select your language with the and buttons and confirm
with the “M” button
:
-Select 1-Label Mode and confirm:
II.
Calculating the stop position:
The label sensor is located exactly 100mm from the peeling edge and its position is fixed.
It is position “
S
” in
below pictures. Because labels have different lengths, we need to calculate the correct stop position, which
we enter in the display menu. The value depends on the length of the labels and the distance between them.
The most comfortable and fastest way to calculate both the stop position and rotation time is with our
online
parameter calculator
https://godex.si/AP16-F/AP16_Calculator.html
If not at your disposal, you must proceed
as follows:
There are 4 scenarios:
Picture 7.1
: in scenario A the correct stop position is 100mm.