AP16-F User Manual V1.2
Page
10
of
20
Label sensor values:
Picture 5.0
Calibration check: Picture 6.0
After measuring the gap, you must measure the
labels.
Place the sensor over the label as shown in picture
5
.0. Make sure that line “B” is in the middle of the
label
and that line “A” crosses the narrowest gap
section. Also ensure that no label cut outs, other
than the gaps, will interfere with line “A” during
operation. Do not move the labels or sensor during
calibration.
Press and hold the “TEACH” button for >3 seconds.
The LED “T” will shine, which indicates the sensor is
in calibration mode. Once you release the key, LED
“T” will start blinking. The sensor is now teaching
itself the label value. The LED bar will indicate the
signal strength. After the process is completed, LED
“T” will go off.
In case the signal strength itself or the difference
with the gap signal is insufficient, the LED-bar will
start blinking. Repeat the procedure in that case.
You may need to restart the device.
After calibrating the sensor, you check whether
the sensor detects the gaps correctly.
See picture 6.0. Move the labels back and forward
over line “A”. If the calibration has been successful,
LED
“o” will shine each time when a gap is
underneath the sensor.