Typical Wiring for Heat Pump HVAC System

THERMOSTAT CONNECTION

C  24VAC COMMON

R  24VAC RETURN

W1  HEAT STAGE 1

O  CHANGEOVER VALVE

G    FAN

Y1  COMPRESSOR STAGE 1

Y2  COMPRESSOR STAGE 2

TYPICAL THERMOSTAT WIRING COLORS.
CAUTION: VERIFY THAT ORIGINAL WIRING
MATCHES. COLORS MAY BE DIFFERENT

HEAT PUMP HVAC SYSTEM

BLUE

RED

WHITE

ORANGE

GREEN

YELLOW

BLACK/BROWN

THERMOSTAT BACK PANEL

Y2 Y1 G  R C   R W1  O

INTERNAL 

R=R 

JUMPER

C

 WIRE IS NOT REQUIRED

FOR BATTERY OPERATION

BATTERIES ARE NOT 
REQUIRED FOR 24VAC 
POWERED SYSTEMS

CONNECT THE

 R 

WIRE TO 

EITHER R TERMINAL.

ARE JUMPERED 

TOGETHER INTERNALLY

NOTE: 

IF HEATING IS OCCURING

WHEN COOOLING IS EXPECTED,
OR VICE-VERSA, CHANGE THE
CHANGEOVER TYPE TO THE
OPPOSITE SETTING.

O or B WIRE

NOTE! 

MOST HEAT PUMP

SYSTEMS DO HAVE THE

 C 

WIRE AND THE 
THERMOSTAT CAN BE
POWERED BY THE 24VAC 
FROM THE HVAC SYSTEM

Содержание GC-TBZ48

Страница 1: ...MODE FAN 74 Off Auto F Model GC TBZ48 Battery Powered Z Wave Thermostat Installation Operation Guide...

Страница 2: ...MRT 11 Entering Menu Mode 12 Menu Mode Naviga on 12 System Menu 13 System Type 13 Fan Type For Standard HVAC systems only 13 Changeover Type For Heat Pump HVAC Systems Only 13 Z Wave Installa on 14 In...

Страница 3: ...format display with white backlight Hea ng and cooling setup display op ons System mode OFF Heat Cool Auto E Heat Fan mode control and display Auto ON Changeover type for Heat Pump HP systems On scree...

Страница 4: ...WHITE ORANGE GREEN YELLOW BLACK BROWN THERMOSTAT BACK PANEL INTERNAL RC RH JUMPER C WIRE IS NOT REQUIRED FOR BATTERY OPERATION C WIRE IS REQUIRED FOR 24VAC OPERATION DEFAULTTHERMOSTAT SETUP TYPE STAND...

Страница 5: ...C SYSTEM BLUE RED WHITE ORANGE GREEN YELLOW BLACK BROWN THERMOSTAT BACK PANEL Y2 Y1 G R C R W1 O INTERNAL R R JUMPER C WIRE IS NOT REQUIRED FOR BATTERY OPERATION BATTERIES ARE NOT REQUIRED FOR 24VAC P...

Страница 6: ...re typically a red wire Ba ery Power Powering the thermostat from ba eries does not require a C wire connec on DO NOT install ba eries if the thermostat is powered by 24VAC They are not required for b...

Страница 7: ...hooting later if needed Terminal Typical Wire Color Function Y YELLOW Cool W WHITE Heat G GREEN Fan R RED 24VAC Return C BLUE 24V Common typically BLUE When the wire is present the thermostat can be p...

Страница 8: ...nel of thermostat Mount the thermostat back panel on the wall See Figure 4 1 Use the two 2 wall anchors and two 2 Phillips screws provided to mount the back panel 2 Level as needed Figure 4 Mounting t...

Страница 9: ...ese are internally jumpered together If installing a Standard HVAC system connect the wires from the HVAC system to the corresponding terminals on the thermostat back terminal block Use the table belo...

Страница 10: ...low as a guideline for connec ng the wires Wire Terminal Y2 Connect to the Y2 terminal 2 stage systems only Y or Y1 Connect to the Y1 terminal G Connect to the G terminal COOL Rc Connect to RC termina...

Страница 11: ...minal Y Connect to the Y1 terminal G Connect to the G terminal R Connect to either R terminal C Connect to the C terminal The C wire 24VAC common Heat Pump systems typically have the C wire connected...

Страница 12: ...s on bo om of case See Figure 12 Install the four 4 type AA ba eries and assemble as shown in Fig 13 Figure 12 Opening Battery Case Cover Figure 13 Battery Installation MODE MODE FAN FAN BODY FRONT PA...

Страница 13: ...h the first press Wait Mode The thermostat has a Minimum O Time MOT delay a er any hea ng or cooling cycle ends This delay prevents rapid hea ng cooling cycles and also provides short cycle protec on...

Страница 14: ...bu ons to scroll through the following menu items Figure 15 Menu Navigation The following menu items are displayed in order SETUP user preference se ngs SYSTEM HVAC system setup Z WAVE install uninst...

Страница 15: ...e hea ng system type For Gas heat select GAS This is the default se ng For Electric heat press the bu ons to change to ELECTRIC Press SELECT to set Press DONE to exit Changeover Type For Heat Pump HVA...

Страница 16: ...thermostat to network 7 Display line should flash WAIT then SUCCESS if Z Wave connec on is made 8 If Z Wave does not connect to controller WAIT then FAIL will flash in status display line 9 If thermo...

Страница 17: ...7 Press SELECT FAN Done FAN Done INFO Menu The INFO menu displays informa on about the thermostat Use the bu ons to scroll through the various items MODEL GC TBZ48 VERSION Thermostat firmware version...

Страница 18: ...s Y or N N Aux Heat Enable Heat Pump Systems only Enables the auxiliary heat opera on Typically the auxiliary heat will be heat strips in a heat pump system Y or N N 2nd Stage Heat Enable Enables the...

Страница 19: ...egrees 2 Hea ng Stage 2 O Threshold Sets the delay from setpoint that stage 2 hea ng stops Stage 2 turns o at setpoint Delta Stage 2 0 to 6 degrees 0 Aux Heat On Threshold Sets the delta from setpoint...

Страница 20: ...ive displayed System is ON and cooling blinking System is ON and cooling Minimum Run Time MRT delay is active NOTE Degrees C Celsius are shown in 5 degree increments Degrees F Farenheit are shown in 1...

Страница 21: ...l system mode Heat E for Emergency Heat will be displayed if the HVAC System Type is set to Heat Pump If there is a compressor failure with the Heat Pump system se ng the mode to Emergency Heat will a...

Страница 22: ...the hea ng setpoint lower if the cooling setpoint is set below the current hea ng setpoint A 3 degree separa on is maintained between the hea ng and cooling setpoints The same is true for raising the...

Страница 23: ...s Use the FAN bu on to select the HVAC system s fan mode Auto Fan automa cally operated by the HVAC system normal se ng On Manual Fan mode Fan stays on un l mode is changed back to Auto independent of...

Страница 24: ...can be set to 0 which will keep the backlight on con nuously SENSOR CALIBRATION Change the temperature calibra on by 7 degrees Press the UP or DOWN arrow bu ons to change to the desired display temper...

Страница 25: ...DONE DONE INFO Menu The INFO menu displays informa on about the thermostat Use the bu ons to scroll through the various items MODEL NTBZ48 VERSION Thermostat firmware version ZWAVE Z Wave firmware ve...

Страница 26: ...acy 1 F 0 5 C Remote Control Via Z Wave Standard Gas Electric HVAC Systems 2 stage hea ng 2 stage cooling Heat Pump HVAC System 3 stage hea ng 2 stage cooling Thermostat Connections Uses standard ther...

Страница 27: ...could void the user s authority to operate the equipment Industry Canada Notices IC 9374A TBZ48 This device complies with Industry Canada license exempt RSS standard s Opera on is subject to the follo...

Страница 28: ...the USA and Canada Dial 855 2GIG TECH 855 244 4832 Email 2gigtechsupport nortek com Visit website for technical support hours of operation For technical support outside of the USA and Canada Contact...

Отзывы: