Auto Equalize:
The GP-PWM-10 has an automatic equalize feature that
will charge and recondition your batteries once a month at a higher
voltage to ensure that any excess sulfation is removed.
This feature is only available when Flooded batteries are
selected.
7.4 Viewing the Controller Display Information
To toggle between Battery Voltage, PV Charging Current, Battery State of
Charge (SOC) and ampere hours charged since last reset, press the
B Button
.
Push the
B Button
to show the
battery voltage.
Icons Displayed
: Battery SOC, Volt
Symbol (V)
Push the
B Button
to show the PV
charging current.
Icons Displayed
: Arrow, Ampere
Symbol (A), Battery SOC