What causes a warning signal and when are the warnings
triggered?
Connection
Warning
Notes
LCD
Battery 1
reverse
polarity
“POL” on LCD
and constant
audible alarm
Battery 2
reverse
polarity
Battery 2 status
display doesn’t
show
Battery 1 must be
connected with
correct polarity
for unit to be
powered on
PV reverse
polarity
“POL” on LCD
and constant
audible alarm
PV short
circuit
Unit shows moon
symbol when PV
is connected and
in bright sunlight
*must have
bright sunlight
on PV too
Why does the battery SOC % never reach 100%?
A 100% value will only appear after a 2 hour Boost or Equalize charge
has completed. The charge voltage must be maintained for an extended
period of time to replenish the energy in the battery bank back to its rated
capacity.
If the charge voltage cannot be maintained continuously, then the actual
time it takes to complete Boost or Equalize charging may take much
longer than 2 hours, even more than 1 day.
If loads are consuming more power than the solar panels can supply,
then the battery bank cannot be charged to 100%.