5.2 - Calibration Procedure

Calibration procedure for mechanical TECH-FLOW,MAT-FLOW, R-FLOW meters:

Fill the container up to a measured quantity.

If the amount displayed does not match the measured quantity, the meter must be calibrated. Make sure 

the pump is off and the system is not under pressure before moving onto the next point.
Remove the sealing plug and turn the calibration screw anticlockwise to 

reduce the quantity displayed or clockwise to increase it (a full turn 

changes the quantity displayed by about 2 litres).

Put the sealing plug back.

Repeat the previous points until calibration is acceptable.

 CAUTION: if the amount of liquid dispensed is less than 5 litres, the device will not allow 

calibration.

PROBLEMS: POSSIBLE CAUSES:

SOLUTIONS:

The meter does 

not read

Suction filter clogged

Clean the filter

Meter placed incorrectly

Check the direction arrow of the liquid on the body; if the meter has been installed 

upside down it won’t work

Incorrect reading 

precision

Flow rate too low or too high

check the technical specifications for the flow rate limits (Chap. 12.2)

Incorrect calibration

Follow the procedure for a new calibration (Chap. 6.2)

Air inside the system

Check for any air intake leaks and make sure the pump does not draw in air

6 - TROUBLESHOOTING

7 - MAINTENANCE

7.1 - Cleaning

TECH-FLOW, MAT-FLOW, R-FLOW meters do not have a suction filter. It is advisable to add a suction 

filter of at least 40 mesh to prevent any residues from interfering with the mechanical parts measuring the 

fluid. To clean the filter, see the instruction manual provided with the filter used.

If the meter is to be scrapped, its parts are to be given to companies specialised in disposing of and 

recycling industrial waste, as shown on the table below:

9 - DEMOLITION AND DISPOSAL

9.1 - Disposal Instructions

PARTS TO BE DISPOSED OF

DISPOSAL METHOD

PACKAGING

The packaging consists of biodegradable cardboard which can be sent to companies for normal pulp recycling.

METAL PARTS

The metal parts, whether painted or aluminium and stainless steel, are usually recycled by companies specialised in the scrap 

metal industry.

PARTS OF A DIFFERENT NATURE

Other parts of the system in which the meter is installed, such as pipes, rubber gaskets, plastic parts and wiring, are to be given to 

companies specialised in disposing of industrial waste.

APPLICABLE REGULATIONS 

FOR CUSTOMERS IN THE 

EUROPEAN UNION

The European Directive 2002/96/EC states that the equipment bearing this symbol on the product and/or on the packaging is 

not to be disposed of with unsorted municipal waste. The symbol indicates that this product must not be disposed of with 

normal household waste. It is the responsibility of the owner to dispose of these products and the other electrical and 

electronic equipment through specific collection facilities appointed by the government or by local authorities.

Содержание Adam Pumps MAT FLOW 3C

Страница 1: ...nza 46 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com UM001 06 2020 rev 06 TECH FLOW 3C 4C MAT FLOW 3C 4C R FLOW 3C 4C ITALIANO lingua origin...

Страница 2: ...Soc con Socio Unico or by sending a request to info adampumps com The person authorised to compile the technical file and draw up the declaration is Davide Stassi as legal representative The use and m...

Страница 3: ...in use Do not blow compressed air through the meter Prevent liquids from drying inside the meter Do not alter or modify the product Alterations or modifications to the product may invalidate the appro...

Страница 4: ...install the TECH FLOW MAT FLOW or R FLOW meter as instructed on the back fluid direction arrow The meters can have fluid outlet upwards downwards to the left or to the right 4 GENERAL INDICATIONS 4 1...

Страница 5: ...AT FLOW R FLOW meters do not have a suction filter It is advisable to add a suction filter of at least 40 mesh to prevent any residues from interfering with the mechanical parts measuring the fluid To...

Страница 6: ...ified or tampered with The product is used in an area with power supply defects voltage changes current phase shift etc The product is used without the supplied suction filter inside or outside the pu...

Страница 7: ...indicativo 30 03 2012 Data Approvato 1 di 1 Foglio 2 3 4 6 8 5 7 9 TF3A1 Propriet Componente Adam Pumps 3C DESCRIPTION Q TY 1 TF014N BOTTOM COVER 1 2 TF013N TOP COVER 1 3 TF015G SIDE COVER WITH HOLE 2...

Страница 8: ...2000 RESET CAP 1 4 TF044 TF045 NUMERATOR HEAD 1 5 TF069 TF069 MAT FLOW COVER 1 6 OR040 OR040 O RING 130x3 NBR 70 1 7 MA984 MA983 FACEPLATE 1 8 MA071 MA071 MADE IN ITALY LABEL 1 9 13101006 13101006 SCR...

Страница 9: ...EAR SHAFT Z 61 11 Z 61 23 1 8 TF102 SHAFT BUSHING 3MM 1 9 TF103 GEAR WHEEL Z61 Z11 1 10 TF104 GEAR WHEEL Z62 1 11 TF105 CONIC PINION SHAFT 1 12 TF106 BUSHING CONIC SHAFT 1 13 TF107 CONIC PINION Z14 1...

Страница 10: ...OW MAT FLOW MADE IN Adam Pumps S p A Soc con Socio Unico via della resistenza 46 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com tutte le dime...

Отзывы: