background image

40

 Key Fob Arm/Disarm Sound

The system can be set so when it’s armed or disarmed by a wireless key fob, a beep will sound 
through the internal and external sounders to indicate that the key fob’s signal was received. This 
helps in installations where the Control Panel is not visible or there are no other system status 
indications at the key fob’s location.

KEY FOB ARM/DISARM SOUND

 

OFF (reg

u

l

a

s

etting)

 

ON

 Key Fob Disarm After Alarm Sound

The system can be set so when it’s disarmed with a wireless key fob 

after

 an alarm has occurred, a 

special series of beeps will sound through the internal and external sounders. This option serves as a 
safety alert to warn you to approach the premises with caution as an intruder may still be present.

KEY FOB DISARM AFTER ALARM 

SOUND

 

OFF (reg

u

l

a

s

etting)

 

ON

★ 

IMPORTANT: 

If you return to the premises and hear the special beeps when disarming 

with the key fob, USE CAUTION! The special beeps indicate that an alarm has occurred 
while you were gone. AN INTRUDER MAY STILL BE ON THE PREMISES. LEAVE 
IMMEDIATELY AND CONTACT THE POLICE FROM A SAFE LOCATION.

 Exit Delay Restart

The Exit Delay Restart option will extend the Exit Delay 

one time

 if you need to re-enter the premises. 

When the system is armed in the Away Mode, the Exit Delay gives you time to leave without setting 
off the alarm. With the Exit Delay Restart option, re-entering the premises after you have left, 

but 

before the Exit Delay timer expires

, will restart the Exit Delay timer, giving you the full length of 

time to leave again. The restart option only works once, each time the system is armed.

EXIT DELAY RESTART

 

ON (reg

u

l

a

s

etting)

 

OFF

 Cancel Time

To limit responses to false alarms, a “cancel” message will be sent to the Central Monitoring Station 
if the system is disarmed within a preset period of time after an alarm is triggered. The alarm report 
is always sent, but it will be followed by a cancel report if you disarm the system within the preset 
time.

This option helps the Central Monitoring Station to determine whether you accidently caused the 
alarm or if the alarm report was caused by an intruder. It also lets the Central Station know that you 
have returned to the premises. Even if a cancel message is sent, the Central Station will verify the 
alarm and possibly dispatch help. The cancel message may be processed by the Central Station at a 
later time depending on system programming.

CANCEL TIME

 

5 Min

u

te

s

 (reg

u

l

a

s

etting)

_________ Min

u

te

s

 Installer Set Options

Содержание Wireless Security System

Страница 1: ...CNTRL LINEAR P N 230083 AX1 INK BLACK MATERIAL 20 LB MEAD BOND WITH 80 LB WHITE COATED COVER SIZE 5 500 X 8 500 SCALE 1 1 FOLDING ALBUM FOLD BINDING SADDLE STITCH WARNING Owner s Instruction Notice No...

Страница 2: ...tely over the telephone The Control Panel displays helpful information regarding the system and sensor status system and alarm history and trouble alerts Being fully supervised the GO control Security...

Страница 3: ...21 Fire 21 Emergency 21 System Trouble Alerts 22 Trouble Alert Icon 22 Nighttime Trouble Alert Holdoff 22 System Status Icons 23 AC Power Icon 23 Phone Line Failure Icon 23 Backup Battery Status Icon...

Страница 4: ...e Master User Code that can assign and maintain the other seven User Codes One of the eight User Codes functions as a Duress User Code Controlling the system with this code gives the appearance of nor...

Страница 5: ...r and interior sensors are armed and can trigger an alarm When the system is armed in the Stay Mode only the perimeter sensors are armed and can trigger an alarm Both arming modes offer an Exit Delay...

Страница 6: ...s RED after an alarm while system is still armed Indicator flashes during power outages system on battery backup Flashes GREEN when ALL sensors are closed ready to arm Flashes ORANGE when ANY sensor i...

Страница 7: ...nside the door jambs Depending on your installation there may be other types of sensors shown below Be sure your installer shows you all the sensors installed in your system Motion Sensor Smoke Detect...

Страница 8: ...the system status and offers three buttons for ARM MENU and STATUS It also displays the time and date If messages alarm or trouble alerts are pending the Security Screen will display buttons indicatin...

Страница 9: ...em and can be turned on or off Turning on the burglary protection part of the security system is called Arming the System The burglary protection part of the system can be armed in two modes Stay Mode...

Страница 10: ...closed The button will not be lit if ANY sensors are open The SECURITY button on the display s Home Screen will light green if all sensors are closed The SECURITY button will be lit orange if ANY sen...

Страница 11: ...sensor can be serviced the sensor can be manually bypassed so the rest of the system can be armed Manual bypasses remain in place until they are manually removed NOTE Bypassed sensors offer no protec...

Страница 12: ...sing a predetermined door and disarm the system before an alarm is triggered When arming the system in Stay Mode an Entry Delay option check box is shown on the Control Panel s Arming Screen Normally...

Страница 13: ...he displayed sensors NOTE BYPASSED SENSORS WILL NOT BE ABLE TO TRIGGER AN ALARM To bypass sensors you will need to enter a User Code unless the installer has set the system for Quick Bypass On the Arm...

Страница 14: ...d doors programmed for delay causing those entrances to instantly trigger the alarm if they are opened in Away Mode With the Entry Delay disabled the system will have to be remotely disarmed with a wi...

Страница 15: ...s the installer has set the system for Quick Bypass On the Arming Screen two check box options can be used with Away Mode 4 The system can be armed without an Entry Delay All perimeter doors will trig...

Страница 16: ...AR FAST REPEATED BEEPS INSTEAD OF THE NORMAL ENTRY DELAY BEEPS USE EXTREME CAUTION AN INTRUDER MAY STILL BE PRESENT INSIDE THE BUILDING WAIT OUTSIDE AND USE A CELL PHONE TO CALL A FRIEND NEIGHBOR OR L...

Страница 17: ...display will show the order that alarms occurred The alarm memory will automatically clear the next time the system is armed You can also check the CLEAR ALARM HISTORY button and press OK to manually...

Страница 18: ...or windows the system will not allow arming to Stay Mode with a wireless key fob All open sensors must be bypassed at the Control Panel first Key Fob Arming to Away Mode To arm the system to Away Mod...

Страница 19: ...tay Mode with a wireless keypad All open sensors must be bypassed at the Control Panel first Wireless Keypad Arming to Away Mode To arm the system to Away Mode using a wireless keypad enter a User Cod...

Страница 20: ...mergency alarm before you sense a problem and the fire alarm is sounding follow these steps If flames and or smoke are present yell FIRE to alert anyone else around 1 Evacuate all occupants from the p...

Страница 21: ...mmends the following placement for smoke detectors Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household The equipment s...

Страница 22: ...ws doors stairs and rooftops that can be used 3 to escape Indicate escape routes for each room Keep these route free from obstructions and post copies of the escape routes in every room Assure that al...

Страница 23: ...d the siren will sound for its preset time or until a User Code is entered to silence the alarm Panic The PANIC police emergency button sends an immediate panic report to the Central Monitoring Statio...

Страница 24: ...right corner that is the number of current trouble alerts The trouble alert icon will flash until the trouble alerts are acknowledged then it will light constant until all the troubles are corrected...

Страница 25: ...Test Mode Icon When the system is placed in System Test Mode the test mode icon will flash in the status bar of the display during the testing Remote Installer Access Icon When the system is being re...

Страница 26: ...of unread messages Urgent messages will display a red message icon with an attention symbol in the upper right corner of the icon Reading Messages When a message icon appears follow these steps to re...

Страница 27: ...check the types of 2 messages to display Press ALL to check all types press NONE to un check all types Press OK to return to the message list The filters will reset selecting all types when your mess...

Страница 28: ...elephone remote control system feature is optional It must be enabled by your installer before it can be used Calling the System Your installer selects whether your system supports the remote telephon...

Страница 29: ...tem will wait up to 60 seconds for each remote command before automatically hanging up If you already know the remote command telephone key number you can enter it before the command announcement fini...

Страница 30: ...On the Toolbox Screen 1 of 3 4 press USER CODES Enter the Master User Code 5 the factory setting is 1111 The Users Screen displays three 6 users at a time Use the and arrows to scroll through the lis...

Страница 31: ...ress CREATE DURESS USER Enter a four digit code for the new 3 Duress User Code and press OK Enter the Code again to confirm 4 the code and press OK A confirmation screen will 5 display press OK Secret...

Страница 32: ...nts always display regardless of the filters selected These events include Walk test started or terminated Programming mode started or terminated To view the system history log use the following steps...

Страница 33: ...of the sensor s wireless signal A list of each sensor will be 6 displayed Use the and arrows to scroll through the list Go to each sensor listed and trigger it 7 For door or window sensors open and c...

Страница 34: ...owing steps On the Home Screen press 1 SECURITY On the Security Screen press 2 MENU On the Menu Screen press 3 TOOLBOX Use the 4 and arrows to select Toolbox Screen 3 of 3 On the Toolbox Screen 3 of 3...

Страница 35: ...OTECTION AND PROPER SYSTEM OPERATION To test the cellular radio use the following steps On the Home Screen press 1 SECURITY On the Security Screen press 2 MENU On the Menu Screen press 3 TOOLBOX Use t...

Страница 36: ...CURITY On the Security Screen press 2 MENU Note the two check boxes on the Menu 3 Screen The CHIME check box button turns the chimes on or off for all the system s sensors The VOICE check box button t...

Страница 37: ...volume The level can be adjusted from 1 to 12 using the buttons on each end of the bar When finished press 7 OK BacklightTimeout The backlight timeout sets the length of time that the display stays li...

Страница 38: ...pires the system 7 will return to the Toolbox Screen Touch Screen Calibration If the touch screen display buttons are not responding properly use the display calibration option to reset the display To...

Страница 39: ...LBOX On Toolbox Screen 1 of 3 4 press the arrow On the Toolbox Screen 2 of 3 5 press SET DATE TIME Use the 6 and arrows to set the current month day and year Press NEXT Use the 7 and arrows to set the...

Страница 40: ...ugh the designated exit entry door without setting off the alarm During the Exit Delay beeps sound and faster beeps sound during the last 10 seconds EXIT DELAY 60 Seconds regular setting _________ Sec...

Страница 41: ...ile the system is armed This allows you to leave the premises without having to disarm and rearm the system When the Quick Exit option is on a QUICK EXIT button will display on the security screen Pre...

Страница 42: ...will extend the Exit Delay one time if you need to re enter the premises When the system is armed in the Away Mode the Exit Delay gives you time to leave without setting off the alarm With the Exit D...

Страница 43: ...system for no dialer delay DIALER DELAY 30 Seconds regular setting _________ Seconds 2 Way Voice The system can connect with a Central Station operator so they can converse with people in the premises...

Страница 44: ...lass B computing device in accordance with Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarante...

Страница 45: ...omer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment opera...

Страница 46: ...company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone extension cord The customer should be aware that complian...

Страница 47: ...IPMENT MUST BE CHECKED BY A QUALIFIEDTECHNICIAN AT LEAST EVERYTHREEYEARS Important Power Supply Notice The Control Panel is powered by a plug in power supply In case the power supply becomes unplugged...

Страница 48: ...y kind of fire every time In general detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed violent explosions escaping gas improper storage of flammab...

Страница 49: ...ective product free and clear of all liens and encumbrances to the Company or its distributor and The product must not have been abused misused or improperly maintained and or repaired during such per...

Страница 50: ...15 18 CLEAR button 14 Color display 4 Control Panel features 4 CREATE DURESS USER button 29 D Date 37 DELETE USER button 29 Deleting a User Code 29 Dialer delay 41 DISARM button 14 Disarming from Away...

Страница 51: ...emote installer access icon 23 S Secret duress button 29 SECURITY button 14 Security screen 6 Sensor bypassing 9 Sensor test 31 Service information 45 Set date and time 37 SET DATE TIME button 37 SILE...

Страница 52: ...Copyright 2009 230083 AX1 Technical Support 866 670 1591 www 2gig com...