GNB TUBULAR-LMX Скачать руководство пользователя страница 8

 Manganese 

   less 

than 

0.007 

ppm

 

Nitrates (as NO3)   

 

less than 10 ppm

 

Nitrites (as NO2)   

 

less than 5 ppm

 

Ammonia (as NH4)  

 

less than 5 ppm

 

Chlorides    

 

 

less than 25 ppm

Before watering

• Make sure that the battery is disconnected from all charging equipment.

• Make sure that the battery is properly cleaned.

• Make sure that you are working with safety glasses.

Water only after charging.

11. 

SERVICE AND PARTS

Your local GNB sales representative has more information regarding the full range of maintenance 

and repair service available.  GNB can also supply all of your battery, charger, and accessory device 

replacement part needs.  For more information in the U.S.A. and Canada, call 1-888-563-6300.  All 

others, please contact your local GNB battery sales representative.

12. RECYCLING

U.S. Federal and State Regulations require that lead acid batteries be handled and disposed 

of in compliance with strict guidelines.  GNB offers disposal service for lead acid batteries.   

Call 1-888-438-5865 to arrange a pick-up or to get additional information.

GB4013 2016-10

GNB Industrial Power

USA – Tel:  877.462.4636  
Canada – Tel: 800.268.2698

www.gnb.com

A Division of Exide Technologies

A Division of Exide Technologies

A Division of Exide Technologies

Содержание TUBULAR-LMX

Страница 1: ...ashbasins are required 1 5 Batteries produce hydrogen and oxygen gas during charge Keep open flames away Do not check electrolyte level with a cigarette lighter or match Use a flashlight or permanent lights Switch on off away from the top of the battery Do not smoke or create sparks 1 6 Lift batteries with a certified approved hoist crane lift truck or similar equipment Move batteries with trucks ...

Страница 2: ...r with an I E I charging profile in order to achieve a minimum 45 day watering interval To achieve a minimum 90 day watering interval GNB requires the use of a GNB charger with a Tubular LMX charging profile Open the vent caps from each cell and check to see that the electrolyte level is above the plate separators If it is obvious that the electrolyte has spilled out of any cells replace it with e...

Страница 3: ... lead acid batteries the electrolyte temperature must not exceed 110 F 43 C If the battery is continuously operated at or above this temperature the service life of the battery will be severely diminished Under normal operating conditions battery electrolyte temperature should be maintained between 60 100 F 15 38 C Following charging the battery should be allowed to cool down or rest approximately...

Страница 4: ...d water at the end of the charging period when the battery is fully charged and the charger has tapered to its finish rate See Section 9 When using a GNB SCR200 charger with a Tubular LMX charging profile After each 90 calendar days of operation to 80 DOD at 5 days per week or when the specific gravity in the cells reaches 1 335 to 1 345 add water at the end of the charging period when the battery...

Страница 5: ...ctrolyte levels above the plate separators but no higher than 1 8 from the bottom of the vent well Check the electrolyte level quarterly or as necessary depending on battery use prior to charging If the level is not visible below the plate separators add just enough water to cover them and then proceed with charging the battery Otherwise defer watering the battery until the end of the charging per...

Страница 6: ...lls is needed Operation of the sensor and lead wire connections should be checked quarterly Sensor operation can easily be checked by lifting it out of the cell If the light goes OFF the sensor is functional and can be reinserted When the sensor is removed from the cell if the light continues to FLASH check the lead wire connections If after confirming the lead wire connections the light continues...

Страница 7: ...nacceptable amounts of particles and debris A 20 micron or finer filter is recommended NOTE This is in addition to the auxiliary 100 micron BWT filter pre packed with the system b Pressure Minimum height of water reservoir must be ten feet For municipal water supply lines a pressure regulator is required Recomended static system pressure is 15 psi Excessive pressure can cause plugs to snap shut pr...

Страница 8: ... of maintenance and repair service available GNB can also supply all of your battery charger and accessory device replacement part needs For more information in the U S A and Canada call 1 888 563 6300 All others please contact your local GNB battery sales representative 12 RECYCLING U S Federal and State Regulations require that lead acid batteries be handled and disposed of in compliance with st...

Отзывы: