background image

CAUTION:

The maximum output of the sound generator falls into the range that can cause

hearing loss according to OSHA regulations. In accordance with NIOSH recommendations,
the user should not use the sound generator for more than eight (8) hours a day when this is
set to a level of 85 dB SPL or above. When the sound generator is set to levels of 90 dB SPL or
above the user should not use the sound generator for more than two (2) hours per day. In no
case should the sound generator be worn at uncomfortable levels.

71

Содержание KE461-DRWC

Страница 1: ...User guide ReSound Receiver In The Ear hearing aids Rechargeable ...

Страница 2: ...Serial number Model number Model number Battery type Rechargeable Dome earmould type Closed dome Small Medium Large Open dome Small Medium Large Power dome Small Medium Large Tulip dome RIE earmould Program Beep Description 1 One beep 2 Two beeps 3 Three beeps 4 Four beeps 2 ...

Страница 3: ... 17 Using your hearing aids 19 Using a telephone 23 Advanced options 28 Wireless accessories 33 Cleaning and caring for your hearing aids 35 General warnings and precautions 45 Hearing aid expectations 48 Troubleshooting 49 Warnings to Hearing Aid Dispensers US only 54 Tinnitus Management 57 Regulatory information 72 Technical specifications 79 Additional information 83 3 ...

Страница 4: ...4 ...

Страница 5: ...ental operating principle of hearing aids is to receive amplify and transfer sound to the eardrum of a hearing impaired person For devices including a Tinnitus Sound Generator module The Tinnitus Sound Generator module is a tool to generate sounds to be used in a Tinnitus Management Program to temporarily relieve patients suffering from Tinnitus For devices including a dome The dome is intended to...

Страница 6: ...This accessory is intended to be used by the same age group as the hearing aid The accessory is intended to be used by lay persons 6 Introduction ...

Страница 7: ...Your hearing aid 1 Receiver wire 2 Receiver 3 Dome an open dome is shown 4 Push button 5 LED 6 Microphone inlets 7 Left right indicator 8 Serial number and model 1 2 3 4 5 6 6 6 7 8 Your hearing aid 7 ...

Страница 8: ...ip dome Closed dome Open dome Power dome Custom earmould The closed open and power domes are available in different sizes Tulip domes are one size Domes are all light grey Only use domes supplied by ReSound 8 Your hearing aid ...

Страница 9: ...attery is built in and cannot be replaced Use of other batteries may present a risk of fire explosion or chemical burn Dispose of rechargeable product according to local regulations Please recycle when possible Do not dispose the rechargeable product as household waste or attempt to burn it as it may explode Batteries are harmful to the environment Therefore never try to burn them dispose of your ...

Страница 10: ...y reasons use only the charger supplied by ReSound Use of other chargers may invalidate any approval or warranty To save battery power turn off your hearing aids when they are not in use Low battery warning When the batteries are low on power your hearing aids reduce the volume and play a melody every 15 minutes until they are empty and turn off 10 Preparing your hearing aids for use ...

Страница 11: ...e minutes indicates that battery power is too low The table below shows how the hearing aid functions are affected as the power level declines Battery level Signal Hearing aid Remote control Streaming Fully charged P P P Low 4 even tones P P x Depleted 3 even tones and 1 longer tone P x x You can check the battery status by placing the hearing aid in the hearing aid charger Premium charger only Yo...

Страница 12: ...r the other for your right Do not swap them Please pay attention to this when cleaning storing and inserting the hearing aids Left hearing aid Right hearing aid You might want to ask your hearing care practitioner to mark your hearing aids with a coloured Left and Right indication Left is blue and Right is red 12 Placing your hearing aids in your ears ...

Страница 13: ... Hang the hearing aid over the top of your ear 2 Hold the receiver wire where it bends and gently place push the receiver dome into your ear canal 3 Push the dome far enough into your ear canal so that the wire rests against your head You can check in a mirror Placing your hearing aids in your ears 13 ...

Страница 14: ...modify the shape of the receiver wire yourself Sport lock If you lead an active life your hearing aids may come loose To avoid this situation your hearing care professional can attach and adjust a sport lock to the receiver To insert a hearing aid with a sport lock 1 Insert the hearing aid as usual 2 Tuck the sport lock into the bottom part of the indentation above your earlobe 14 Placing your hea...

Страница 15: ...earmould between your thumb and index finger and position the sound outlet into your ear canal 2 Slide the earmould into your ear with a gentle twisting move ment Move the earmould up and down and press gently Opening and closing your mouth may assist 3 Place the hearing aid behind your ear and ensure it is secure When properly inser ted your hearing aids should fit snugly and comfortably Placing ...

Страница 16: ... earmould it may help to pull your ear up and outward with the opposite hand CAUTION Never attempt to modify the shape of the hearing aids earmoulds domes or receiver wires yourself 16 Placing your hearing aids in your ears ...

Страница 17: ...s from your ears If your hearing aids have domes follow these instructions 1 Lift the hearing aid off your ear 2 Hold the receiver wire with your thumb and forefinger where it bends and pull the dome out of your ear canal Removing your hearing aids from your ears 17 ...

Страница 18: ...ntarily 2 Using your thumb and index finger gently pull the earmould not the hearing aid or the wire loose from your ear If your earmould has a removal cord pull it gently to assist The removal cord is a separate line that is additionally attached to the earmould if requested Remove the earmould completely by twisting it gently 18 Removing your hearing aids from your ears ...

Страница 19: ... LED flashes 3 times Your hearing aids also turn off automatically when you place them in the charger Premium charger only and they turn on automatically when you remove them from the charger Your hearing aids always start on program 1 at the pre set volume Smart Start Smart Start delays the time before your hearing aid turns on after you remove the hearing aid from the charger With this function ...

Страница 20: ... switch between programs You will then hear one or more beeps The number of beeps indicates which program you have selected Press and hold for 1 second short melody until streaming begins If your hearing aids have been paired with more than one wireless device pressing for one more second will switch to the next device A short press will end streaming and start the program you left Press and hold ...

Страница 21: ...push button and fill in the following table with your new settings Action Default setting New setting New setting Short press Change program 1 sec press Activates streaming NOTE Some features are configurable during your fitting session Ask your hearing care professional about the best settings for you For convenience you may control your hearing aids from the ReSound Smart 3D app or the ReSound R...

Страница 22: ... change programme or turn it on or off Action Light Turn on Press and hold the button for 5 seconds Flash Turn off Press and hold the button for 5 seconds Flashes three times Enter flight mode optional Press and hold the button for 9 seconds Four times double flashes 22 Using your hearing aids ...

Страница 23: ...to your ear canal or hold it close to the hearing aid microphones as illustrated 2 If you hear whistling try holding the telephone in the same position for a few seconds The hearing aid may be able to cancel the whistling 3 You can also try holding the telephone slightly away from the ear NOTE Depending on your needs your hearing care professional may activate a function specifically for telephone...

Страница 24: ...s accessories to enhance listening capabilities Phone Now optional By placing a magnet on the telephone receiver your hearing aids automatically switch the telephone program on when the receiver is close to your ear When you remove the receiver from your ear the hearing aids automatically return to the previous listening program NOTE Ask your hearing care professional to enable Phone Now as one of...

Страница 25: ...pacemakers and defibrillators in question If the manufacturer cannot issue a statement we recommend keeping the magnet or a telephone equipped with the magnet 30 cm 12 away from magnetically sensitive devices e g pacemakers Phone Now precautions If you experience frequent signal loss or noise during calls move the magnet to another place on the telephone receiver Only use magnets supplied by ReSou...

Страница 26: ...thoroughly Use a recommended cleaning agent 2 Remove the foil from the magnet 3 Place the magnet on the phone CAUTION If you experience frequent signal loss or noise during calls move the Phone Now magnet to another place on the telephone receiver Only use magnets supplied by ReSound 26 Using a telephone ...

Страница 27: ... hearing aids have enabled the Comfort Phone functionality the hearing aid on the non phone ear automatically attenuates Do not cover the phone loudspeaker opening with the magnet If the function does not work to your satisfaction moving the magnet to another position may improve ease of use and comfort If your hearing aids do not switch to the telephone program consistently try repositioning the ...

Страница 28: ...cludes ReSound Assist Live With this service you can get face to face assistance from your hearing care professional from home All you need is a smart device with Internet enabled This allows you to 1 Request assistance remotely to adjust your hearing aids to be a better fit for you 2 Keep your hearing aids up to date with the latest software to ensure the best performance possible NOTE Your heari...

Страница 29: ...nly works if your smart device is connected to the Internet Your hearing care professional will provide information regarding this option and how it works with the ReSound Smart 3D app Using your hearing aids with iPhone iPad and iPod touch The advanced models of our hearing aids are Made for iPhone iPad and iPod touch which allow for direct audio streaming and control from these devices Advanced ...

Страница 30: ... send and receive signals to and from the hearing aids via smartphones Our smartphone apps must only be used with our hearing aids for which they were designed and we take no responsibility if the app is used with other hearing aids Do not disable app notifications Install updates to keep the app working correctly The app must only be used with ReSound hearing aids for which they are intended and ...

Страница 31: ...this option can be added by your hearing care professional However in some areas you are requested to turn off wireless communication CAUTION When boarding a flight or entering an area where RF transmitters are prohibited wireless functionality must be deactivated Turning off wireless communication enter Flight Mode 1 Turn off your hearing aid 2 Press the button for 9 seconds 3 Your hearing aid wi...

Страница 32: ...Activating wireless communication exit Flight Mode 1 Turn your hearing aid off and then on 2 Wireless communication will be activated after 10 seconds 32 Advanced options ...

Страница 33: ...e to your hearing aids at a volume level that suits you ReSound Remote Control allows you to adjust the volume mute your hearing aids and change programs ReSound Remote Control 2 allows you to adjust the volume or mute your hearing aids change programs and see settings at a glance on its display ReSound Phone Clip streams phone conversations and stereo sound directly to both hearing aids and it do...

Страница 34: ...for streaming audio from a computer or music player NOTE Ask your hearing care professional for more information on the range of ReSound wireless accessories For use of wireless functionality only use ReSound wireless accessories For further guidance please refer to the user guide of the relevant ReSound wireless accessory 34 Wireless accessories ...

Страница 35: ...ot wear your hearing aids when putting on cosmetics perfume aftershave hairspray suntan lotion etc These might discolour the hearing aid or get into the hearing aid causing damage 4 Do not immerse your hearing aid in any liquid 5 Keep your hearing aids away from excessive heat and intense direct sunlight The heat may deform the shell damage the electronics and deteriorate the surface 6 Do not swim...

Страница 36: ...se of a drying kit is recommended WARNING Always turn your hearing aids off while cleaning and maintaining them Cleaning tools 1 Soft cloth 2 Brush for cleaning Use the brush on all surfaces and orifices Also use your brush for daily cleaning and battery handling 3 Wire loop Use the wire loop to clean the earmould 4 Magnet Use the magnet to lift and replace the battery 36 Cleaning and caring for y...

Страница 37: ...the brush WARNING Do not use force to press the bristles on the small brush into the inlets because the microphones may be damaged CAUTION Do not use alcohol or other solvents to clean your hearing aid the protective coating will be damaged Cleaning and caring for your hearing aids 37 ...

Страница 38: ... your domes every 3 months or more often according to the advice of your hearing care professional Incorrect dome replacement can result in a dome being left in your ear when you remove your hearing aid If you suspect that you have a dome stuck in your ear contact your hearing care professional Only use original ReSound consumables e g domes and wax filters Open closed and power domes The illustra...

Страница 39: ...ff the receiver and discard This may require a bit of force 2 Push the new dome over the ribbed end of the receiver 3 Check that the dome is securely mounted by carefully lifting the lower part of the dome and verifying that the collar completely covers the ribbed end of the receiver 4 OK Cleaning and caring for your hearing aids 39 ...

Страница 40: ... instructions 1 Remove the used dome by pulling it off the receiver and discard This may require a bit of force 2 Push the largest petal back then press the tulip dome over the ribbed end of the receiver 40 Cleaning and caring for your hearing aids ...

Страница 41: ...g that the collar completely covers the ribbed end of the receiver 4 Push the larger petal toward the receiver This illustration shows a cor rectly mounted tulip dome Ensure the large petal is outside the small petal Cleaning and caring for your hearing aids 41 ...

Страница 42: ...ng care professional for advice on how often you need to do this It will depend on how much earwax your ears produce If you wear a dome remove it before following this process for replacing the wax filter You will need your box of wax filter tools Box of 8 wax filter tools The wax filter tool has two functions a removal tip to collect the used filter and a replacement tip with a white filter 42 Cl...

Страница 43: ...take out one of the tools Each tool has a small hook removal tip in one end and a new wax filter in the other 3 Insert the removal tip into the used wax filter and then pull the tool straight out It is important to pull it straight and not on an angle Cleaning and caring for your hearing aids 43 ...

Страница 44: ...ntly press the replacement straight into the sound outlet until the outer ring is touching the sound outlet 3 Pull the tool straight out your new wax filter will remain in place Re attach your dome or a replacement dome Only use original ReSound consumables e g domes and wax filters 44 Cleaning and caring for your hearing aids ...

Страница 45: ...s radio equipment mobile telephones contain less energy and will not damage hearing aids However they have the potential to momentarily affect the sound quality or temporarily create undesired sounds from the hearing aids 3 Do not wear hearing aids in mines oil fields or other explosive areas unless those areas are certified for hearing aid use 4 Do not allow others to use your hearing aids 5 Hear...

Страница 46: ...ere radio frequency emission is prohibited 9 If a hearing aid is broken do not use it 10 A power hearing aid can produce very loud sound to compensate for a severe or profound hearing loss There is therefore a risk of further impairing the remaining hearing 11 External devices connected to the electrical input must be safe according to the requirements of IEC 60601 1 IEC 60065 EN IEC 62368 1 or IE...

Страница 47: ...ireless devices Although unlikely nearby electronic devices may be affected In that case move the hearing aid away from the affected electronic device 2 Use only original parts from the manufacturer e g wax guards 3 Only connect your hearing aids to accessories intended and qualified to be used with your hearing aids General warnings and precautions 47 ...

Страница 48: ...ting from organic conditions Consistent use of the hearing aid is recommended In most cases infrequent use does not permit you to get full benefit from it The use of a hearing aid is only part of hearing rehabilitation and may need to be supplemented by auditory training and instructions in lip reading 48 Hearing aid expectations ...

Страница 49: ...volume very loud Reduce the volume Is the receiver wire broken or is the earmould clogged Visit your hearing care professional Are you holding an object e g a hat or a telephone mouthpiece close to the hearing aid Move your hand away to create more space between the hearing aid and the object Is your ear full of wax Visit your physician Troubleshooting 49 ...

Страница 50: ... professional Is your ear full of wax Visit your physician Sound is distorted spluttering or weak Is the receiver wire broken or the earmould clogged Consult your hearing care professional Battery drains very quickly Did you leave your hearing aid switched on for long periods of time Always turn off your hearing aids when you are not using them e g during the night Is the hearing aid 3 4 years old...

Страница 51: ...sitting correctly in the charger Reinsert the hearing aid in the charger See the user manual for your charger Is the hearing aid charger charged Premium charger only or plugged into a power source Plug the charger in to a power source See the user manual for your charger Troubleshooting 51 ...

Страница 52: ...ng aids as described in this user guide Can I damage a battery by incorrect use Only if you expose it to extreme temperatures or excessive physical force Is it required to remove the hearing aids when fully charged No Can I interrupt the charging of the hearing aids and the hearing aid charger Yes Should I use up all battery power before charging again No 52 ...

Страница 53: ...remove the hearing aids from the charger they will not turn on automatically as normally Press the push button for 5 seconds to turn the hearing aids on manually Premium charger only Does the battery heat up when charging There is a slight temperature increase at the end of the char ging process Can I charge at low temperatures If the hearing aid temperature is below 0 C 32 F it will not charge im...

Страница 54: ...pective user has any of the following conditions 1 Visible congenital or traumatic deformity of the ear 2 History of active drainage from the ear within the previous 90 days 3 History of sudden or rapidly progressive hearing loss within the previous 90 days 4 Acute or chronic dizziness 5 Unilateral hearing loss of sudden or recent onset within the previous 90 days 6 Audiometric air bone gap equal ...

Страница 55: ... evaluation the physician will give you a written statement that states that your hearing loss has been medically evaluated and that you may be considered a candidate for a hearing aid The physician will refer you to an audiologist or a hearing care professional as appropriate for a hearing aid evaluation The audiologist or hearing care professional will conduct a hearing aid evaluation to assess ...

Страница 56: ...ous or personal beliefs that preclude consultation with a physician The exercise of such a waiver is not in your best health interest and its use is strongly discouraged Children with hearing loss In addition to seeing a physician for a medical evaluation a child with a hearing loss should be directed to an audiologist for evaluation and rehabilitation because hearing loss may cause problems in la...

Страница 57: ...ou may hear the therapeutic sound of a continuous or fluctuating noise Indications for use of the TSG module US only The Tinnitus Sound Generator module is a tool to generate sounds to be used in a Tinnitus Management Program to temporarily relieve patients suffering from Tinnitus The target population is primarily the adult population over 18 years of age This product may also be used with childr...

Страница 58: ...nerates sounds to be used in tinnitus management programs to relieve suffering from tinnitus Explanation of how the device works The TSG module is a frequency and amplitude shaped white noise generator Noise signal level and frequency characteristics can be adjusted to the specific therapeutic needs as determined by your doctor audiologist or hearing care professional Your doctor audiologist or he...

Страница 59: ...or hearing care professional can set the TSG Module so that it becomes audible exclusively in such surroundings The overall sound level can be adjusted via a volume control Your doctor audiologist or hearing care professional will review with you the need for having such a control For hearing aids where ear to ear synchronization is enabled your hearing care professional can also enable environmen...

Страница 60: ...your tinnitus as well as the sound used In a majority of instances the TSG module can also be set to mask the tinnitus sound so to provide temporary relief by introducing a more pleasant and controllable sound source TSG volume control The sound generator is set to a specific loudness level by the hearing care professional When switching the sound generator on the volume will have this optimal set...

Страница 61: ...ia hearing aid push buttons can be enhanced with wireless control from a TSG control app on a smartphone or mobile device This functionality is available in supported hearing aids when a hearing care professional has enabled the TSG functionality during fitting of the hearing aid NOTE To use smartphone apps the hearing aid must be connected with the smartphone or mobile device 61 ...

Страница 62: ...e noise signal which can be shaped with the following configurations High pass filter Low pass filter 500 Hz 2000 Hz 750 Hz 3000 Hz 1000 Hz 4000 Hz 1500 Hz 5000 Hz 2000 Hz 6000 Hz 8000 Hz The white noise signal can be modulated in amplitude with an attenuation depth of up to 14 dB 62 ...

Страница 63: ...adaches perceived decrease in auditory function or increase in tinnitus perception you should discontinue use of sound generator and seek medical evaluation Children and physically or mentally challenged users will require training by a doctor audiologist hearing care professional or the guardian for the insertion and removal of the hearing aid containing the TSG module Important notice for prospe...

Страница 64: ...f the ear are often referred to as otolaryngologists otologists or otorhinolaryngologists The purpose of medical evaluation is to assure that all medically treatable conditions that may affect tinnitus are identified and treated before the sound generator instrument is used The sound generator instrument is a tool to generate sounds to be used with appropriate counselling and or in a tinnitus mana...

Страница 65: ...s if improperly used Sound generators should be used only as advised by your doctor audiologist or hearing care professional Sound generators are not toys and should be kept out of reach of anyone who might cause themselves injury especially children and pets 65 ...

Страница 66: ...user should discontinue use of the sound generator and seek medical evaluation To prevent unintended usage by paediatric or physically or mentally disabled users the volume control must if enabled be configured to only provide a decrease of the sound generator output level Children and physically or mentally disabled users will require guardian supervision while wearing the TSG hearing aid 66 ...

Страница 67: ...e prospective user has any of the following conditions 1 Visible congenital or traumatic deformity of the ear 2 History of active drainage from the ear within the previous 90 days 3 History of sudden or rapidly progressive hearing loss within the previous 90 days 4 Acute or chronic dizziness 5 Unilateral hearing loss of sudden or recent onset within the previous 90 days 6 Audiometric air bone gap ...

Страница 68: ...worn at uncomfortable levels Tinnitus Sound Generator precautions 1 Should the user develop any side effects from using the sound generator such as dizziness nausea headaches perceived decrease in auditory function or increase in tinnitus perception the user should discontinue use of the sound generator and seek medical evaluation 2 Discontinue use of the sound generator and consult promptly with ...

Страница 69: ...e TSG module used for adjusting the sound generator output level To prevent unintended usage by paediatric or physically or mentally disabled users the volume control must be configured to only provide a decrease of the sound generator output level 5 Children and physically or mentally disabled users will require guardian supervision while wearing the TSG hearing aid 6 Adjustment of the Tinnitus S...

Страница 70: ...er that the prospective user has any of the following conditions 1 Visible congenital or traumatic deformity of the ear 2 History of active drainage from the ear within the previous 90 days 3 History of sudden or rapidly progressive hearing loss within the previous 90 days 4 Acute or chronic dizziness 5 Unilateral hearing loss of sudden or recent onset within the previous 90 days 6 Audiometric air...

Страница 71: ...ecommendations the user should not use the sound generator for more than eight 8 hours a day when this is set to a level of 85 dB SPL or above When the sound generator is set to levels of 90 dB SPL or above the user should not use the sound generator for more than two 2 hours per day In no case should the sound generator be worn at uncomfortable levels 71 ...

Страница 72: ...replaced by new products or products manufactured from new or serviceable used parts or repaired using new or refurbished replacement parts The warranty period of hearing aids is designated on your warranty card which is provided by your hearing care professional For hearing aids that require service please contact your hearing care professional for assistance Hearing aids that malfunction must be...

Страница 73: ... C 113 F at a relative humidity of 90 non condensing An atmospheric pressure between 500 hPa and 1100 hPa is appropriate During transport or storage the temperature should not exceed the limit values of 20 C 4 F to 60 C 140 F at a relative humidity of 90 RH non condensing for a limited time 73 ...

Страница 74: ...ned to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does...

Страница 75: ...orms to the Essential Requirements according to Annex I of Council Directive 93 42 EEC for medical devices MDD Hereby GN ReSound A S declares that the radio equipment types LXR45 are in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address www declarations resound com In US FCC CFR 47 Part 15 subpart C Other identified...

Страница 76: ...ber will become invalid Type designations Hearing aid type designations for models included in this user guide are LXR45 FCC ID X26LXR45 IC 6941C LXR45 This device includes an RF transmitter which operates in the frequency band of 2 4 GHz 2 48 GHz Hearing aid variants Mini Receiver In the Ear RIE hearing aids of type LXR45 with FCC ID X26LXR45 IC number 6941C LXR45 are available in the following v...

Страница 77: ...r Follow instructions for use Do not dispose of your hearing aids and batteries with ordinary household waste Your hearing aids and batteries should be disposed of at sites intended for electronic waste or returned to your hearing care professional for safe disposal Please ask your local hearing care professional concerning disposal of your hearing aid NOTE There may be specific regulations in you...

Страница 78: ...Complies with ACMA requirements Complies with IMDA Standards DA105282 Complies with IMDA standards 78 ...

Страница 79: ...dB Maximum output 90 dB SPL input Max HFA 113 109 dB SPL Total harmonic distortion 500 Hz 800 Hz 1600 Hz 0 5 0 8 0 5 Equivalent input noise w o noise reduction 21 dB SPL 1 3 Octave Equivalent input noise w o noise reduction 1600 Hz 9 dB SPL Frequency range IEC 60118 0 2015 100 8000 Hz Expected operating time 30 Hours Data in accordance with ANSI S3 22 2014 IEC 60118 0 2015 Measured in a 2cc couple...

Страница 80: ...uivalent input noise w o noise reduction 24 dB SPL 1 3 Octave Equivalent input noise w o Noise reduction 1600 Hz 11 dB SPL Frequency range IEC 60118 0 2015 100 8060 Hz Expected operating time 30 Hours Data in accordance with ANSI S3 22 2014 IEC 60118 0 2015 Measured in a 2cc coupler Expected operating time of the rechargeable battery depends on active features the use of wireless accessories heari...

Страница 81: ... 500 Hz 800 Hz 1600 Hz 0 3 0 7 0 5 Equivalent input noise w o noise reduction 22 dB SPL 1 3 Octave Equivalent input noise w o noise reduction 1600 Hz 10 dB SPL Frequency range IEC 60118 0 2015 100 6750 Hz Expected operating time 30 Hours Data in accordance with ANSI S3 22 2014 IEC 60118 0 2015 Measured in a 2cc coupler Expected operating time of the rechargeable battery depends on active features ...

Страница 82: ...uivalent input noise w o noise reduction 23 dB SPL 1 3 Octave Equivalent input noise w o noise reduction 1600 Hz 9 dB SPL Frequency range IEC 60118 0 2015 130 4920 Hz Expected operating time 30 Hours Data in accordance with ANSI S3 22 2014 IEC 60118 0 2015 Measured in a 2cc coupler Expected operating time of the rechargeable battery depends on active features the use of wireless accessories hearin...

Страница 83: ...e met Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer Redistributions in binary form must reproduce the above copyright notice this list of conditions and the following disclaimer in the documentation and or other materials provided with the distribution THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS...

Страница 84: ...ple badge means that an accessory has been designed to connect specifically to iPhone iPad and iPod touch models and has been certified by the developer to meet Apple performance standards Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards 2020 GN Hearing A S All rights reserved ReSound is a trademark of GN Hearing A S Apple the Apple l...

Страница 85: ...Notes 85 ...

Страница 86: ...Notes 86 ...

Страница 87: ...Notes 87 ...

Страница 88: ...stralia Tel free 1800 658 955 resound com New Zealand GN Hearing New Zealand Limited Ground Floor North Entrance 4 Fred Thomas Drive Takapuna Auckland 0622 Tel free 0800 900 126 resound com Singapore GN Hearing Pte Ltd 456 Alexandra Road 22 01 Singapore 119962 Tel 65 6320 9388 resound com Any issues relating to the EU Medical DeviceDirective 93 42 EEC or EU Radio Equipment Directive 2014 53 EU sho...

Отзывы: