Programming
The following parameters can be set in the order in which they appear below:
•
LED display brightness
•
Measuring range selection
•
Decimal point
The following additional parameters can also be set for instruments with limit
values:
•
Relay switching performance
•
Switching point values
•
Limit value hysteresis
Enabling Programming
In order to enable programming, program protection (Lock) must be released,
i.e. contact between terminals 10 and 11 must be interrupted. If programming
has not been enabled,
Loc
is displayed when the programming mode is
accessed.
Programming Description
The measuring instruments are programmed at the factory as indicated on
the serial plate. If programming has been enabled, the basic settings can be
changed with the three keys at the front panel.