Section 5
MAINTANCE
Electromagnet
Electrical Connections
on the magnet terminal block should be checked annually. The electrical connections
should be clean and tight. Discoloration is a sign that the connection is overheating and must be rectified before
further use of the magnet.
Water Hoses
should be checked regularly for water leaks. Any leaks should be rectified before further use of
the magnet.
Motorized Rotating Drive
Rotating Platen
contains nylon ball bearings and does not require periodic lubrication.
Worm Gear
should be lubricated annually by smearing the worm gear with a coating of a graphite based
grease.