TROUBLESHOOTING
These belows are to troubleshoot a trouble for operator. Please ask to a supplier for a trouble that is not listed in the belows.
SYMPTOMS
CAUSE OF TROUBLE
TROUBLESHOOTING
Power is not turned on
1. POWER S/W is ON/OFF
1. Check whether power is being supplied properly.
2. CIRCUIT BREAKER is activated
2. Check whether the Circuit Breaker is activated.
Press the Projecting Part on the Circuit Breaker to reuse.
This trouble would be occurred continuously by more than 2 times,
ask to a supplier.
Roller is not activated
1. Roller is not pressured.
1. Check the position of Roller Pressure Adjustable Handle.
2. Front Table Safety Lever is not fixed at 2. Fix the safety lever at fixing hole.
Fixing Hole.
Refer to "Front table safety lever" of Main Device.
3. Safety Cover is opened.
3. Check whether the safety cover or safety cover lever is opened.
Roller is not heat up
1. Wrong Temp. Setup at Control Panel
1. Refer to "Temp. Setting Button" of Control Panel.
2. Power Cord or Heater Wire is short.
2. Ask to a supplier.
Single Side laminated results
1. Decurling value is too high or too low. 1. Refer to "Decurling Device" of Main Device.
are curled
Double Side laminated results
1. Top Roll Film tension is too high.
1. Turn the film tension adjustable handle to the left to reduce its tension.
are curled upward
2. Bottom Roll Film tension is too low.
2. Turn the film tension adjustable handle to the right to increase its tension.
Double Side laminated results
1. Top Roll Film tension is too low.
1. Turn the film tension adjustable handle to the right to increase its tension.
are curled downward
2. Bottom Roll Film tension is too high.
2. Turn the film tension adjustable handle to the left to reduce its tension.
Laminated results has below "A"
1. Laminating Roller pressure is too low.
1. Increase Laminating Roller pressure.
Refer to "Roller Pressure Adjustable Handle" of Main Device.
Laminated results has below "B"
1. Laminating Roller pressure is too high. 1. Reduce Laminating Roller pressure.
2. Laminated results are too hot.
2. Activate the cooling fan motor.
Refer to "FAN" of Control Panel.