background image

Page 8 of 12 

General Machine Products Co., Inc. 

fit the innerduct 

clamp 

(A)

 and 

tighten the two 

retaining cap 

screws 

(H)

. Do 

not over tighten 

the retaining 

screws. 

10. 

For installing 

duct tubes, tube 

end caps will 

need to be fit-

ted, the duct 

tubes may also need to be pressurized. 

11. 

Apply a smear of silicon grease to the edge of the cable / tube

(s) entry point on the junction box base and lid. 

12. 

The cable blowing machine should be set up ready to install 

the new cable/duct-tube(s), (refer to procedure in the cable blow-

ing machine operator and maintenance manual).  The cable / duct-

tube(s) must be fed through the short slave length of innerduct 

from the cable blowing machine and into the existing innerduct fed 

into the Cable Overblowing Junction Box by approx. 6 - 15’ (2 – 

5m). 

13. 

Close the Cable Overblowing Junction Box lid and secure by 

tightening all 4 retaining cap screws. Do not over tighten. 

14. 

The system is now ready to begin installing the new cable / 

duct tube(s). 

15. 

On completion of the installation it may be necessary to re-

move the short length slave innerduct with a duct slitter. 

16. DO NOT OPEN THE CABLE OVERBLOWING JUNCTION 

BOX WHILE UNDER PRESSURE

.   

Always check that the air pressure gauge on the blowing machine 

has reduced to zero before opening. 

EXISTING

 DUC

BLO

WE

Содержание 89066

Страница 1: ...produced or transmitted in any form whatsoever without the written permission of General Machine Products Co Inc CABLE OVERBLOWING JUNCTION BOX OPERATION MAINTENANCE MANUAL GMP 3111 Old Lincoln Hwy Tr...

Страница 2: ...21 15 Add Allen Key reference Combined 89066 and 89067 in same manual A Konschak 03 11 30 15 Added 2 SDR A Konschak 04 01 17 17 Updated color code on 33218 33219 A Konschak CONTENTS 1 Safety Instruct...

Страница 3: ...ng to prevent ear damage 10 Stay clear of the pressurized innerduct 11 Only use the equipment for its intended purpose 12 When operating machine always wear eye protection hard hat safety shoes and le...

Страница 4: ...cities Please observe the following precau tions when operating the Cable Blowing Machine 1 Compressed air can cause flying debris This could cause personal injury Always wear personal protective equi...

Страница 5: ...existing cable can exit the Cable Overblowing Junction Box through an opening that has 3 cable seal slots one of which will house the seal to suit the size of the existing cable The third branch is t...

Страница 6: ...and the duct size Duct Size 1 1 4 SDR 1 1 2 SDR 2 SDR Installation Principle Viscous Drag Viscous Drag Viscous Drag Max Operat ing Pressure 175 psi 12 Bar 175 psi 12 Bar 175 psi 12 Bar Length 12 305mm...

Страница 7: ...e attached e Lubricated 5 Position the Cable Overblowing Junction Box into the manhole duct or trench 6 Remove the lid and open the innerduct clamps F A place the existing innerduct C into the innerdu...

Страница 8: ...nce manual The cable duct tube s must be fed through the short slave length of innerduct from the cable blowing machine and into the existing innerduct fed into the Cable Overblowing Junction Box by a...

Страница 9: ...ls should be cut to length and glued into the grooves in the junction box housing upper and lower halves 4 Always ensure that the cable seals are in good condition and replace if damaged or worn For b...

Страница 10: ...uel Emergency stop button pressed Damaged lead between Power Pack and blowing machine EXCESSIVE AIR LEAKAGE FROM OVERBLOWING JUNCTION BOX Damaged cord seal Cable seals worn incorrect size installed wr...

Страница 11: ...se give as much information as possible to ensure correct identification and supply of spare parts RECOMMENDED SPARES LIST 7 SPARES PART No Description Qty required 89147 Seal Cord 10 89588 Sealing Co...

Страница 12: ...Page 12 of 12 General Machine Products Co Inc GMP 3111 Old Lincoln Hwy Trevose PA 19053 USA TEL 1 215 357 5500 www gmptools com...