4. OPERATING PROCEDURE

 

 

It is imperative that all persons using, operating or maintaining this power pack 
be fully trained and competent to do so, and have read the entire operating 
manual. 
 
General Machine Products Co., Inc. and CBS Products Ltd cannot be held re-
sponsible for misuse of this equipment. 
 
The power pack is designed to work with an open center control valve.  There-
fore it is imperative that the hoses are connected to a system having the facility 
prior to starting the engine. 

 

Connecting Hoses

 

 

The hydraulic power pack must be connected by the two detachable hoses to 
the driven machine by plugging in the male/female quick release couplings be-
fore starting the engine. 
 

IMPORTANT:

 Do not try to start the engine on the Power Pack until the hoses 

between the Power Pack and the remote equipment have been connected. 
Do not disconnect the hydraulic hoses when the power pack is running (if the 
engine continues to run serious overheating will occur as the oil continues to 
pass through the relief valve). 

 
Hydraulic Oil Level

 

 
Check hydraulic oil level and top off with the appropriate grade of hydraulic oil 
(refer to 3.0 specification for details) or equivalent if necessary, each time the 
power pack is used. 
 

Starting the Engine

 

 

Refer to the engine manufacturer manual before starting the engine. 

 

NOTE:The engine manufacturer recommends the addition of a gas stabilizer to 
unleaded gas if the unit is to be stored for an extended period.  This prevents 
the build up of gum and varnish in the gas, keeps the carburetor and gas system 
clean and improves engine performance. 

Содержание 32481

Страница 1: ...ne Products Co Inc All rights reserved No part of this publication may be copied reproduced or transmitted in any form whatsoever without the written permission of General Machine Products Co Inc POWER PACK OPERATION MAINTENANCE GMP 3111 Old Lincoln Hwy Trevose PA 19053 USA TEL 1 215 357 5500 FAX 1 215 357 6216 EMAIL info gmptools com September 2009 USA Ver 1 Manual P N 32839 ...

Страница 2: ...Page 2 of 16 General Machine Products Co Inc Rev Date Details Author 01 11 01 01 Original issue D North 02 09 01 09 US Version 1 A Konschak REVISION HISTORY ...

Страница 3: ...s Co Inc CONTENTS 1 Safety Instructions 2 General Description 3 Specification 4 Operating procedures 5 Maintenance 6 Troubleshooting Guide 7 Service History Record 8 Recommended Spares List APPENDICES Appendix 1 Hydraulic Drawing Warranty ...

Страница 4: ...nments 10 Beware of pinch points involved with rotating components 11 Beware of hot surfaces machine uses hydraulics 12 When operating machine always wear eye protection hard hat safety shoes and leather gloves machine operates with hydraulic oil at 2030 psi 13 Some component and assembly parts are in excess of 55 lbs 25kg When lifting care must be taken insure sufficient man power lifting gear is...

Страница 5: ...of cardboard Caution Do not use your hands Oil may be hot 3 Do not exceed working pressure of hydraulic hoses 4 Visually inspect hoses regularly and replace if damaged 16 Machine may cause additional fire hazard if involved in an existing fire due to hydraulic oils 17 The machine must be operated on firm ground 18 Only use the machine for its intended purpose 19 Do not tamper with pressure relief ...

Страница 6: ...d displacement gear pump fitted with an integral pressure relief valve The hydraulic circuit has an oil tank fitted with a suction filter and a replaceable return line filter to protect the pump and motor The tank is also fitted with a filler breather and sight level gauge The hydraulic power pack is connected to the remote equipment via detachable dual hoses fitted with male female quick release ...

Страница 7: ...Honda Engine Type GXV 160KI 5HP Approximate operating time is 45 minutes with a full tank of gas at maximum R P M Hydraulic Oil Type Shell Tellus T 32 Hydraulic Oil Tank Capacity 6 US gallons For Engine Details refer to manufacturers manual Model Engine Flow Pressure No type l min US gal min bar psi 32481 Honda 15 4 94 1350 ...

Страница 8: ...arting the engine IMPORTANT Do not try to start the engine on the Power Pack until the hoses between the Power Pack and the remote equipment have been connected Do not disconnect the hydraulic hoses when the power pack is running if the engine continues to run serious overheating will occur as the oil continues to pass through the relief valve Hydraulic Oil Level Check hydraulic oil level and top ...

Страница 9: ...ass when the power pack is on level ground The circuit is fitted with two filters only one of these requires replac ing Replace the Return Line Filter when the filter gauge is in the red indicating higher return pressure i e clogged filter The gauge is found on the side of the fil ter housing Gas Engine Refer to manufacturer s manual 1 Unscrew the return line filter top cap with a 24mm box wrench ...

Страница 10: ...Duct rod Pusher Insure hoses are connected from power pack to blower if they are not connected or have a faulty coupling engine will not turn over Contaminated gas Difficult to Start Engine Check above points Insure gas has additional additive Engine may be flooded Check hydraulic valve on blower unit is switched off Check spark plug Engine is Running Erratic Insure additive is mixed with gas Dama...

Страница 11: ...Page 11 of 16 General Machine Products Co Inc Service no Date Carried out by Record of service repair 7 SERVICE HISTORY RECORD ...

Страница 12: ...evose PA 19053 USA TEL 1 215 357 5500 FAX 1 215 357 6216 E MAIL info GMPtools com Website www GMPtools com Please give as much information as possible to insure correct identification and supply of spare parts RECOMMENDED SPARES LIST PART No Description Qty required 89154 Filler Breather 1 89157 Oil Level Gauge 1 89159 Suction Filter 1 89156 Wheel pneumatic 2 89163 Return Line Filter 1 ...

Страница 13: ...nc APPENDIX 1 Hydraulic Circuit Ref PART 1 Hydraulic Tank 2 Gas Engine 3 Hyd Pump Relief Valve 4 Suction Filter 5 Filler Breather 6 Oil Level Gauge 7 Quick Release Coupling High Pressure 8 Quick Release Coupling Low Pressure 9 Return Line Filter ...

Страница 14: ... right to request that the product or part be returned to us for examination and cannot be responsible for user charges incurred in the replacement of any product GMP s agreement to repair or replace is also subject to its inspection of the product and verification of the defect 3b Subject to immediate written notification of a defect or malfunction GMP will repair or replace that product or part ...

Страница 15: ...on improper operation alteration or negligence in storage or handling 5a THE ABOVE WARRANTIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL WARRANTIES OF MERCHANTABILITY FITNESS FOR PURPOSE OR OTHER WARRANTIES OR GUARANTEES OF ANY KIND OR DESCRIPTION EXPRESS OR IMPLIED 5c GMP S SOLE LIABILITY AND THE PURCHASER S SOLE REMEDY FOR A FAILURE OF A PRODUCT OR PART UNDER THIS LIMITED WARRANTY AND FOR ANY AND ALL ...

Страница 16: ...Page 16 of 16 General Machine Products Co Inc GMP 3111 Old Lincoln Hwy Trevose PA 19053 USA TEL 1 215 357 5500 FAX 1 215 357 6216 EMAIL info gmptools com ...