PSD1001 

- SIL 3 - SIL 2 Quad ch. Power Supply for Hazardous Area Equipment 

G.M. International ISM0023-11 

Parameters Table 

Must 

be 

Hazardous Area/ 

Hazardous Locations 

Device Parameters 

PSD1001 Associated 

Apparatus Parameters 

Must 

be 

Hazardous Area/ 

Hazardous Locations 

Cable Parameters 

Uo / Voc = 23.6 V 

Ui / Vmax 

In the system safety analysis, always check the Hazardous Area/Hazardous Locations devices to conform with the related system documentation, if the device is Intrinsically Safe check 
its suitability for the Hazardous Area/Hazardous Locations and gas group encountered and that its maximum allowable voltage, current, power (Ui/Vmax, Ii/Imax, Pi/Pi) are not exceeded 
by the safety parameters (Uo/Voc, Io/Isc, Po/Po) of the PSD1001 Associated Apparatus connected to it. Also consider the maximum operating temperature of the field device, check that 
added connecting cable and field device capacitance and inductance do not exceed the limits (Co/Ca, Lo/La, Lo/Ro) given in the Associated Apparatus parameters for the effective gas 
group. See parameters on

 

enclosure side and the ones indicated in the table below: 

PSD1001 Terminals 

Ch1 

Ch2 

13 - 14 

15 - 16 

Ch3 

Ch4 

9 - 10 

11 - 12 

Io / Isc = 88.2 mA 

Ch1 

Ch2 

13 - 14 

15 - 16 

Ch3 

Ch4 

9 - 10 

11 - 12 

Po / Po = 519 mW 

Ch1 

Ch2 

13 - 14 

15 - 16 

Ch3 

Ch4 

9 - 10 

11 - 12 

 

Ii/ Imax 

 

Pi / Pi 

 

PSD1001 Terminals 

Ch1 

Ch2 

13 - 14 

15 - 16 

Ch1 

Ch2 

9 - 10 

11 - 12 

PSD1001 Associated 

Apparatus Parameters 

Ci / Ci  C cable 

 

(IIC-A, B) 

Co / Ca = 130 nF 

Co / Ca = 970 nF 

Co / Ca = 3.5 µF 

(IIB-C) 

(IIA-D) 

 

Ch1 

Ch2 

13 - 14 

15 - 16 

Ch1 

Ch2 

9 - 10 

11 - 12 

Li / Li L cable 

 

(IIC-A, B) 

Lo / La = 4.5 mH 

Lo / La = 18.2 mH 

Lo / La = 36.5 mH 

(IIB-C) 

(IIA-D) 

Ch1 

Ch2 

13 - 14 

15 - 16 

Ch1 

Ch2 

9 - 10 

11 - 12 

Li / Ri device and 

L cable / R cable 

 

(IIC-A, B) 

Lo / Ro = 68.6 µH/

 

Lo / Ro = 274.4 µH/

 

Lo / Ro = 548.9 µH/

 

(IIB-C) 

(IIA-D) 

NOTE for USA and Canada: 

IIC equal to Gas Groups A, B, C, D, E, F and G 
IIB equal to Gas Groups C, D, E, F and G 

IIA equal to Gas Groups D, E, F and G 

Содержание PSD1001

Страница 1: ...PSD1001 SIL 3 SIL 2 Quad ch Power Supply for Hazardous Area Equipment ISM0023 11 PSD1001 INSTRUCTION MANUAL SIL 3 SIL 2 Quad channel Power Supply for Hazardous Area Equipment DIN Rail Model PSD1001...

Страница 2: ...10 11 12 Um 250 Vrms 20 C Ta 60 C Approvals DMT 01 ATEX E 042 X conforms to EN60079 0 EN60079 11 EN60079 26 EN61241 0 EN61241 11 IECEx BVS 07 0027X conforms to IEC60079 0 IEC60079 11 IEC60079 26 IEC61...

Страница 3: ...FM FM C Certifications Type Approval Certificate KR for marine applications High Reliability SMD components High Density four channels per unit Simplified installation using standard DIN Rail and plug...

Страница 4: ...device check that added connecting cable and field device capacitance and inductance do not exceed the limits Co Ca Lo La Lo Ro given in the Associated Apparatus parameters for the effective gas grou...

Страница 5: ...Safety Entity Concept allows the interconnection of Intrinsically Safe devices approved with entity parameters not specifically examined in combination as a system when the above conditions are respe...

Страница 6: ...ASS I DIVISION 1 GROUPS A B C D CLASS II DIVISION 1 GROUPS E F G CLASS III DIVISION 1 CLASS I ZONE 0 GROUP IIC SAFE AREA ZONE 2 GROUP IIC T4 NON HAZARDOUS LOCATIONS CLASS I DIVISION 2 GROUPS A B C D T...

Страница 7: ...en installed in Hazardous Area Hazardous Locations or unless area is known to be nonhazardous Warning substitution of components may impair Intrinsic Safety and suitability for Division 2 Zone 2 Explo...

Страница 8: ...eets your actual Installation Intrinsically Safe conductors must be identified and segregated from non I S and wired in accordance to the relevant national international installation standards e g EN...

Отзывы: