3
D1010-054 / 056 / 057
- mV to mA Converter
G.M. International ISM0098-8
Ordering information
Model:
D1010S
1 ch. range –5 to +55 mV
-054
1 ch. range –5 to +35 mV
-056
1 ch. range –5 to +10 mV
-057
Power Bus enclosure
/B
Front Panel and Features
Input from Zone 0 (Zone 20), installation in Zone 2.
-5 to +55 mV Input / 4 to 20 mA Output.
Input and Output short circuit proof.
High Accuracy.
Three port isolation, Input/Output/Supply.
EMC Compatibility to EN61000-6-2, EN61000-6-4.
ATEX, IECEx Certifications.
High Reliability, SMD components.
Simplified installation using standard DIN Rail and plug-in terminal blocks.
250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier.
Not used
Terminal block connections
HAZARDOUS AREA
SAFE AREA
Not used
+ Input Ch 1 for TC
- Input Ch 1 for TC
13
14
15
16
+ Output Ch 1 for Current Source mode
1
- Output Ch 1 for Current Source mode
2
+ Power Supply 24 Vdc
3
- Power Supply 24 Vdc
4