26
Customer Support: 1-866-409-4581
Generator
Spark arrestor maintenance
The generator muffler is equipped with a spark arrestor that must
be cleaned.
Refer to the Maintenance Schedule for regular service intervals.
1. Turn the generator OFF.
2. Have your generator on a flat, level surface.
3. Locate the muffler exhaust port at the rear of the generator.
4.Remove the four bolts holding the muffler cage panel.
5. Loosen and Remove the screw that attaches the spark arrestor
to the exhaust port and remove spark arrestor.
6. Use a wire brush and remove any debris or deposits from the
screen.
7. Inspect the screen for any breaks or tears. If necessary,
replace screen.
8. Replace and tighten screw to reattach the spark plug arrestor
to the exhaust port.
cleaning exterior of Generator
1. Do not spray the generator with water or a garden hose.
2. Wipe surface with a damp cloth or use a soft brush to remove
dirt or dust.
3. Cover generator with a clean cover.
Muffler reaches temperatures that can cause serious
burns if touched.
NEVER touch hot surfaces.
WARNING
HOT SURFACE
Never cover a generator when running or when hot.
Cover a generator only after the generator is cool.
NOTICE
SPARK ARRESTOR SCREEN
spark arrestor