Installation requirements
19
Electrical specifications
Power supply requirements
CAUTION:
The requirements below are specifications for preparing the installation protection.
The fuses/circuit breakers must be prepared according to local regulations, and with adequate
capacity as specified here. The circuit breakers must be suitable for inventor operation.
NOTE:
Specifications on the equipment's name plate is the actual input current and will thus not be
identical to below mentioned.
Supply *
EUR
3W + N + PE,
400 VAC, 50/60 Hz
Fused by 3 × 40 Amps
Cable type: Min. 5 × 16 mm², type H07 RNF
*) Voltage tolerance ± 10%
NOTE:
The power cable(s) must be in accordance with local regulations.
WARNING:
Please be aware of double pole/neutral fusing.
CAUTION:
The fuses must have a breaking capacity of min. 100 kA.
CAUTION:
If a circuit breaker of type ELCB, RCCB, or GFCI is used where leakage to ground is
detected, the trip sensitivity must be 300 mA.
Power consumption
Dry
Compact
Standard
Max
In operate, per phase
(±10%), max.
35000 W (119400
BTU)
37500 W (128000
BTU)
40000 W (136500
BTU)
45000 W (153500
BTU)
May, 2022
Pre-installation Guide
|
Flex-i-Line 520 (XP) Dry/Compact/Standard/Max
Содержание Flex-i-Line 520
Страница 2: ...2 Blank Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...
Страница 6: ...Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...
Страница 12: ...Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...
Страница 20: ...Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...