Pre-installation Guide

|

Flex-i-Line 520 (XP) Dry/Compact/Standard/Max

May, 2022

Содержание Flex-i-Line 520

Страница 1: ...ation Guide Flex i Line 520 XP Dry Compact Standard Max IMPORTANT Please follow the instructions in this guide when installing the equipment May 12th 2022 Edition AE Part No 10084430 English en us Original version ...

Страница 2: ...2 Blank Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...

Страница 3: ...Dry Compact Standard Max This manual is published by Glunz Jensen A S Selandia Park 1 DK 4100 Ringsted Denmark Phone 45 57 68 81 81 E mail gj glunz jensen com Internet www glunz jensen com Copyright May 2022 by Glunz Jensen A S May 2022 Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max ...

Страница 4: ...ts 8 Lifting the crate 10 Required width of passage and doorways 11 Installation requirements 13 Heating and ventilation 13 Installation kit 13 Floor stability 13 Space requirements 14 Free space around the equipment 14 Dimensions and connections 15 Compressed air 17 Solvent connection 17 Exhaust connection 17 Electrical requirements 18 Main power outlet 18 Power cable 18 Electrical specifications...

Страница 5: ...ation Guide help the customer and the Service Technician to prepare the installation site for the arrival and installation of the equipment Notes Cautions and Warnings Notes cautions and warnings in this manual are used and categorized as described below Symbol Meaning Explanation NOTE The operator should observe and or act according to the information in order to obtain the best possible function...

Страница 6: ...Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...

Страница 7: ... s address Make notes of any damages before opening the crate Provide a detailed description and take a photograph of the damage Report any damage of the crate to the shipping company and notify the insurance agent if appropriate before the mishandled package is opened Check the Tilt watch and the Shock watch label that the red mark has not appeared and compare their serial numbers with those on t...

Страница 8: ...andard Max Elevator Compact Dry Tower 2 L 2720 mm 107 1 2270 mm 89 4 2720 mm 107 1 2570 mm 101 2 W 2300 mm 90 6 2300 mm 90 6 2300 mm 90 6 2300 mm 90 6 H 2480 mm 97 6 2480 mm 97 6 2480 mm 97 6 2480 mm 97 6 Weights Equipment only Equipment with crate Processor 520 1800 kg 3970 lbs 2050 kg 4520 lbs Processor 520 XP 2400 kg 5290 lbs 2940 kg 6480 lbs Tower 1 1900 kg 4190 lbs 2350 kg 5180 lbs Pre instal...

Страница 9: ...tandard Max 1860 kg 4100 lbs 2250 kg 4960 lbs Elevator Compact Dry 1900 kg 4190 lbs 2300 kg 5070 lbs Tower 2 1400 kg 3090 lbs 1800 kg 3970 lbs Tower 2 Max 2000 kg 4410 lbs 2400 kg 5290 lbs May 2022 Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max ...

Страница 10: ...quipment off the pallet WARNING The equipment is very heavy equipment It is only possible to lift the equipment off the pallet using a forklift truck or a pallet mover CAUTION Make sure to provide a forklift designed and adequate for lifting a crate of the size and weight as specified in this manual Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...

Страница 11: ...of the doorway is Then More than 2400 mm 94 5 The crated equipment can be transported immediately to the installation site CAUTION May require machine moving skates suitable for transport of very heavy equipment Less than but more than 2400 mm 94 5 2200 mm 86 6 The Service Technician has to unpack the equipment CAUTION May require machine moving skates suitable for transport of very heavy equipmen...

Страница 12: ...Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...

Страница 13: ...10066844 CASTROL SPHEEROL 4601 GREASE 1 pc 10104023 DIRTY SOLVENT LEVEL SENSOR COMPLETE 1 pc 10104014 CABLE EXT PUMP CONTROL FLEX i PRO 1 pc 0 BA 057 SA INLET SOLVENT EXTERNAL BARREL 1 pc 0 BA 058 SA OUTLET SOLVENT EXTERNAL BARREL 1 pc 5 DP 003 KEY LOCK TRIANGLE 1 pc 5 FA 027 HOSE AIR EXHAUST D140 5 m 5 FA 021 TUBE POLYURETHANE D4 6 5 m 7 HA 010 HOSECLAMP 122 142 2 pcs 1 330 029 SAFETY TANK 1 pc 1...

Страница 14: ... proper installation site for the equipment and make sure that the free space around the equipment makes servicing possible The recommended minimum free space around the equipment is specified in the next illustration Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...

Страница 15: ...Installation requirements 15 Dimensions and connections May 2022 Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max ...

Страница 16: ...16 Installation requirements Standard Max Compact Dry Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...

Страница 17: ...legal to empty these types of chemicals into the public sewer system Under all circumstances local regulations applying to the treatment of chemical waste must be followed strictly Exhaust connection Processor exhaust must be connected to the appropriate location directly to the outside If the length of the exhaust hose to the outside is more then 5 meters you have to add an external exhaust pump ...

Страница 18: ...NT COURANT DE FUITE ÉLÉVE RACCORDEMENT Á LA TERRE INDISPENSABLE AVANT DE RACCORDEMENT AU RÉSEAU Power cable NOTE The cable for the main power connection is included with the equipment WARNING The equipment is Class 1 equipment Therefore the equipment must be connected to earth to avoid electrical shocks Please be aware of double pole neutral fusing CAUTION The conductors in the power supply cable ...

Страница 19: ...elow mentioned Supply EUR 3W N PE 400 VAC 50 60 Hz Fused by 3 40 Amps Cable type Min 5 16 mm type H07 RNF Voltage tolerance 10 NOTE The power cable s must be in accordance with local regulations WARNING Please be aware of double pole neutral fusing CAUTION The fuses must have a breaking capacity of min 100 kA CAUTION If a circuit breaker of type ELCB RCCB or GFCI is used where leakage to ground is...

Страница 20: ...Pre installation Guide Flex i Line 520 XP Dry Compact Standard Max May 2022 ...

Страница 21: ... to the installation site See Required width of passage and doorways on page 1 o o E Are there other factors stairs elevators corners obstacles etc which should be taken into account when transporting the equipment If YES please describe o o 2 Power supply YES NO A Make a note of the present supply specifications Number of phases Neutral wire o Voltage V Earth wire o Fused by Amps Frequency Hz B H...

Страница 22: ...nection available according to the requirements as described in chapter Solvent connection on page 17 o o 4 Web registration YES NO A The login and password is necessary to download an available manuals for the equipment Click on Login and then Create new account Fill up the required fields and checkboxes Then click on CREATE NEW ACCOUNT After while the login information will be delivered to the s...