GLP
German Light Production
(V1.05)
21
5.2
Realize the Lamp Change
1. Pull out the main plug!
2. Open the upper shell of the head casing by loosening the 4 Phillips screws.
Two on the front side and 2 on the back side of the head.
3. Open the 3 screws at the lamp sheet and remove it.
4. Remove the old or broken lamp out of the socket.
Attention:
The glass bulb of
the lamp can splinter. For that reason remove the lamp with safety gloves or
some cloth.
5. Put in the new lamp securely into the socket.
Attention:
Use only the original lamp type!
6. Adjust the optimum distance between the lamp
bulb and the lens (1.0-1.5 mm) with the adjusting
screw [
A
]. This can be necessary through
different manufacturer.
7. Close the
Y
Y
P
P
O
O
C
C
2
2
5
5
0
0
B
B
a
a
s
s
i
i
c
c
in reverse order.
8. The running time of the lamp
LA1
can be reseed in
the
Time
Menu.
Attention:
Pay attention on a firm fit of the lamp and on the optimum distance
between the lamp and the lens (1.0 - 1.5 mm)!
5.3 Lamp
adjustment
The optimum distance between the lamp and the lens must be controlled after
every lamp change. The lower deviation amount is
min. 1.0mm
. Running the
fixture within a lower deviation can cause damages of lamp and/or lens.
WARNING:
Disconnect the fixtur e fr om AC p ower
before r e-lamping.
Lamp is h ot! Risk of fire! Protect hands a nd eye s.
Wait at least 15min. Be for e openin g the covers
and removing l amp from th e fixture .
Ma ximum r oom temperature t=45 C
Mi nimum distance fr om flammable materi al d=0 .5m.
Exte rior surface temper ature T=80 C
Not for domestic use.
Ad ju st l am p p o sit io n b y tur n in g sc rew s
an d
A
B
A
B
Be sure that the lamp
bulb never touch the le ns
Screws "A"
Screws "B"
min. distance 1mm
The
Y
Y
p
p
o
o
c
c
2
2
5
5
0
0
B
B
a
a
s
s
i
i
c
c
lamp holder is aligned at the factory. Due to differences
between lamps, fine adjustments may improve light performance.
Pease follow this procedure:
fastening screw
lamp
cover plate
lamp