7
4
Connections
4.1
Power Supply
~90-240 Volt AC, 50-60 Hz, powerCON AC connector
Connected load max. 350 VA (Watt) / 25VA (Watt) per Atom head
<=> T5A (micro-fuse 5x20mm)
Please see printing on the case for the right electronic supply!
Always disconnect from the mains supply for changing the fuse and use
only the above described micro-fuse type.
NEUTRIK® powerCON
The
X4 ATOM PSU 12
is fitted with NEUTRIK® powerCON locking 3 conductor
AC connectors.
The grey connector must be used to draw AC mains power from the fixtures`
throughput sockets and the blue connectors must be used to supply power
at the fixtures` power input socket.
The total number of fixtures in one interconnected chain depends on your
local AC mains voltage but you must never connect more than a total load
of 20A to stay within the limits of the connector. The total load includes all
connected fixtures including the first one in the chain.
Note: The maximum allowed total -
load is 20A including the first fixture
in one interconnected daisy chain.