GLP X4 atom PSU 12 Скачать руководство пользователя страница 5

                                                                                      

GLP German Light Products 

 

X4 Atom PSU12 manual (v1.0)  

from software version: v1.21

 

3

 

Mounting 

 
The 

X4 ATOM PSU 12 

is fully operational whether it hangs or is mounted to 

the wall. It can also be operated in a rack or standing on the floor or table. 
Keep  a  safety  distance  of  min.  0.5  m  towards  any  easily  inflammable 
materials (decoration etc.).  

 

 

Pay attention to the regulations of: BGV C1 (former VBG 70) 

and DIN VDE 0711-217. 

The installation shall be done by qualified staff only. 

 
For  the  various  mounting  positions  of  the 

X4  ATOM  PSU  12

  (sideways  or 

hanging) different accessories kits are available. Through this a safe and firm 
installation is assured. You'll find dedicated connectors on the top side of 
the fixture which should be used.  
 

3.1

 

Operating on the floor, on a table or in a Rack 

The 

X4 ATOM PSU 12 

can directly placed on the floor, a table or inside a 

rack. An additional securing is usually not required. Please pay attention to 
an even and gripping surface and keep at least 10cm space to each side 
for ventilation.  
 

Attention: Make sure not to not block any of the two fan in/outlets on either 
side of the fixture. 

 

3.2

 

Mounting in a hanging or sideways position 

To operate the 

X4 ATOM PSU 12 

in a hanging position an omega bracket 

can be mounted directly to the top side of the PSU using the two Camlock 
connectors. 
It  is  fixed  to  the  fixture  with  fasteners  called  Camlock  quick-release 
connectors. Insert the two fasteners and turn each 90° to lock them. Do the 
opposite to release them again. 
 
Alternatively a half-coupler (clamp or hook) can be mounted directly to the 
top side of the PSU using the M10 x 11mm thread bolt. 
 

Attention:  Never  use  a  longer  bolt  than  11mm  as  this  may  damage  the 
interior of the fixture. 

Содержание X4 atom PSU 12

Страница 1: ...from software version v1 21 support glp de www glp de Instruction Manual PSU12...

Страница 2: ...ck 5 3 2 Mounting in a hanging or sideways position 5 3 3 Securing the Fixture 6 4 Connections 7 4 1 Power Supply 7 4 2 DMX 8 4 3 Output to X4 ATOM Head 8 5 The Menu Field 8 6 DMX Channel Selection DM...

Страница 3: ...LCD Display Menu data entry 2 Safety wire attachment point 2x 3 Fan in outlet 2x 4 Connector panel see below 1 2 3 4 5 6 7 8 9 10 11 5 Mains switch on off 6 Micro fuse 5 x 20mm T5A 250V 7 12 x Output...

Страница 4: ...common rules of technology that are not explicitly mentioned in this manual 6 Use only original GLP spare parts Any structural modification of the system will terminate all warranty claims 7 Please k...

Страница 5: ...r on a table or in a Rack The X4 ATOM PSU 12 can directly placed on the floor a table or inside a rack An additional securing is usually not required Please pay attention to an even and gripping surfa...

Страница 6: ...ty wire Attach the safety wire through the attachment point shown below and connect it to the primary support structure Pay attention to a safe and proper fastening The safety cable must comply with B...

Страница 7: ...PSU 12 is fitted with NEUTRIK powerCON locking 3 conductor AC connectors The grey connector must be used to draw AC mains power from the fixtures throughput sockets and the blue connectors must be us...

Страница 8: ...e PSU and or the connected fixture s 5 The Menu Field DOWN UP MODE ENTER Level1 Level 2 Level 3 Level 4 Remark DMX Start Address 001 Set the DMX start address Special Manual DMX Manual control of all...

Страница 9: ...y contrast PWM Frequ Adj Changes PMW frequency Max Zoom adjust Calibration of Zoom offset LED adjust White adjust red Adjust intensity for red channel White adjust blue Adjust intensity for blue chann...

Страница 10: ...taneous value for Shutter White Instantaneous value for White Blue Instantaneous value for Blue Green Instantaneous value for Green Red Instantaneous value for Red Color Wheel Instantaneous value for...

Страница 11: ...0 5 sec 98 100 248 254 Output 1 3 Intensity Intensity 0 100 0 100 0 255 4 Shutter Shutter closed 0 5 0 15 Random strobe random slow fast 6 18 16 47 Ramp up random slow fast 19 31 48 79 Ramp down rando...

Страница 12: ...ast 63 77 144 199 Strobe Slow to Fast random slow fast 78 98 200 239 Shutter Open 95 100 239 255 14 Color fixed Colors adjustable via RGB 0 2 0 7 Color 01 Red 1 3 5 8 15 Color 02 Amber 1 6 8 16 23 Col...

Страница 13: ...Rainbow Effect Stop 2 50 128 Rainbow Effect 3 slow fast 51 88 129 223 Random colors slow fast 89 100 224 255 24 Red Color mixing system Red 0 100 0 100 0 255 25 Green Color mixing system Green 0 100 0...

Страница 14: ...obe with b o pause random slow fast 63 77 144 199 Strobe Slow to Fast random slow fast 78 98 200 239 Shutter Open 95 100 239 255 41 Color fixed Colors adjustable via RGB 0 2 0 7 Color 01 Red 1 3 5 8 1...

Страница 15: ...w fast 89 100 224 255 51 Red Color mixing system Red 0 100 0 100 0 255 52 Green Color mixing system Green 0 100 0 100 0 255 53 Blue Color mixing system Blue 0 100 0 100 0 255 54 White Color mixing sys...

Страница 16: ...tter Open 95 100 239 255 68 Color fixed Colors adjustable via RGB 0 2 0 7 Color 01 Red 1 3 5 8 15 Color 02 Amber 1 6 8 16 23 Color 03 Warm Yellow 1 9 12 24 31 Color 04 Yellow 1 13 15 32 39 Color 05 Gr...

Страница 17: ...en 0 100 0 100 0 255 80 Blue Color mixing system Blue 0 100 0 100 0 255 81 White Color mixing system White 0 100 0 100 0 255 82 Zoom Wide flood narrow spot 34 3 5 0 100 0 255 83 CTO No function Applic...

Страница 18: ...1 6 8 16 23 Color 03 Warm Yellow 1 9 12 24 31 Color 04 Yellow 1 13 15 32 39 Color 05 Green 1 16 18 40 47 Color 06 Turquoise 1 19 21 48 55 Color 07 Cyan 1 22 24 56 63 Color 08 Blue 1 25 27 64 71 Color...

Страница 19: ...stem Green 0 100 0 100 0 255 107 Blue Color mixing system Blue 0 100 0 100 0 255 108 White Color mixing system White 0 100 0 100 0 255 109 Zoom Wide flood narrow spot 34 3 5 0 100 0 255 110 CTO No fun...

Страница 20: ...ooling will be significantly reduced or damages can occur Regular cleaning will not only ensure the maximum performance but will also allow the fixture to operate reliably throughout its life 7 1 Safe...

Страница 21: ...00ft per output Fuse protection Micro fuse 5x20 mm T10A Operational Parameters Max Ambient Temperature 5 45 C integrated overheating switch 40 113 F Protection IP20 rated Mounting Position Any see rel...

Страница 22: ...GLP German Light Products X4 Atom PSU12 manual v1 0 from software version v1 21 22 9 Dimensions...

Страница 23: ...GLP German Light Products X4 Atom PSU12 manual v1 0 from software version v1 21 23...

Отзывы: