background image

 

 

 

7

 

(instruction version 0.91)

 GLP 

z

 

German Light Production

 

3  The Menu Field / DMX Address and Functions  

You find the control board on the front side of the casing. It allows you 
to make all necessary adjustments of the 

J

J

U

U

N

N

I

I

O

O

R

R

 

 

S

S

C

C

A

A

N

N

 

 

3

3

.

.

 With the 

Mode-

key you get into the main menu. Afterwards you can navigate 

through the menu with the 

Up/Down-

keys. Push the 

Enter-

key to get 

in the next menu level or to confirm your settings. Make them and set 
functions 

ON/OFF

 with the 

Up/Down-

keys. Confirm and save it with 

the 

Enter-

key (the display shows 

OK

). Push the 

Mode-

key to cancel the 

entry and go back to the main menu.

 

MODE ENTER 

UP 

DOWN

MODE 

ENTE

UP DO

WN

LED-Display

 

 

 

 

 

Level 1 

Level 2 

Level 3   Remark 

D001 

 

 

 

Define the DMX start address 

TEST 

 

 

 

Test program of all functions  

AUDI 

ASLW 

 

 

Self-running audio program (slow) 

 

AFST 

 

 

Self-running audio program (fast) 

 

MSTR 

 

 

Master for the audio program 

 

SVPT 

 

 

Basic position for the audio program 

 

SIZE 

 

 

Size for the audio program (NORM-BIG-MID-SMALL) 

LAMP 

 

 

 

Switch on/of the lamp direct at the 

Y

Y

P

P

O

O

C

C

 

 

2

2

5

5

0

0

 

RESE 

 

 

 

Reset 

TIME 

POWR 

 

 

Running time of the fixture (no destructible)  

 

LA1 

 

 

Running time of the lamp (erasable)  

 

LA2 

 

 

Running time of the lamp (no destructible)  

RPAN 

 

 

 

Reverse Pan-direction 

RTLT 

 

 

 

Reverse Tilt-direction 

SPEC 

MANU 

 

 

Manual drive of all device functions 

 

LAAU 

 

 

Automatic lamp start 

 

DLOF 

 

 

Switch off lamp via DMX 

 

DMXI 

 

 

Reed out actual DMX-values 

 

DISP 

D ON 

 

Display On/Off 

 

 

REV 

 

Twist the display 

 

ADJU 

CODE xxxx 

 

Use the code for entering the calibration menu (for 
authorized person only) 

 

 

COLO 

 

Calibration of the color wheel 

 

 

GOBO 

 

Calibration of the gobo wheel 

 

 

PRIS 

 

Calibration of the prism wheel 

 

 

SHT1 

 

Calibration of the shutter 1 

 

 

SHT2 

 

Calibration of the shutter 2 

Å

 DOW

N

  -

  UP 

Æ

 

 

 

POFS 

 

PAN Offset 

 

 

 

TOFS 

 

TILT Offset 

 

 

 

CLRE 

 

Settings in the internal memory (super user only) 

  

  ARES 

 

ADJUST RESET 

 

 

DFSE 

 

 

Call on the default function values 

 

 

TRB1 

 

 

Software settings for the TRB1 board  

 

 

TRB2 

 

 

Software settings for the TRB2 board 

 

 

EFLG 

 

 

Correction of faults 

 

Содержание Junior Scan 3

Страница 1: ...Instruction Manual from software version 1 0 instruction version 0 91 email service glp de Internet http www GLP de...

Страница 2: ...1 instruction version 0 91 GLP z German Light Production This side is intentionally unlabelled...

Страница 3: ...ust the DMX Address D001 8 3 2 The Test Program TEST 8 3 3 The Audio Program AUDI 8 3 4 Lamp On Off LAMP 9 3 5 Reset RESE 9 3 6 Running time of lamp and unit TIME 9 3 7 Invert Pan Movement RPAN 9 3 8...

Страница 4: ...hange 17 6 Change a Gobo 17 6 1 Safety Regulations 17 6 2 Realize the Gobo Change 18 7 Maintenance and Cleaning the J JU UN NI IO OR R S SC CA AN N 3 3 18 7 1 Safety Regulations 18 7 2 Circumference a...

Страница 5: ...GLP z German Light Production instruction version 0 91 4 1 Description of the Device Display Data entry Lens Relay bracket Air outlet 2x Air inlets Casing screws Figure 1 1...

Страница 6: ...AC before you open the J JU UN NI IO OR R S SC CA AN N 3 3 Please do not touch the bulb of the lamp if you are not absolutely sure it is cold Danger of BURNING 5 Never look directly into the beam of t...

Страница 7: ...you have to use a stipulated safety wire that can hold at least 10 times the weight of the fixture Install it through the handle and connect it with the truss support Pay attention to a safe and prope...

Страница 8: ...program SVPT Basic position for the audio program SIZE Size for the audio program NORM BIG MID SMALL LAMP Switch on of the lamp direct at the Y YP PO OC C 2 25 50 0 RESE Reset TIME POWR Running time...

Страница 9: ...the display shows OK or press the Mode key to cancel The DMX Address is stored also while switching off the J JU UN NI IO OR R S SC CA AN N 3 3 3 2 The Test Program TEST Test The Test program allows y...

Страница 10: ...the shutter is closed at the same time Use an external controller or the manual drive mode see also chapter 3 9 1 on page 10 3 5 Reset RESE RESE Press the Enter key to run a reset of all fixture funct...

Страница 11: ...NU This function allows you to drive all the fixture functions manually Select the desired function with the Up Down keys and confirm with Enter Now choose the desired value with the Up Down keys and...

Страница 12: ...he lamp via DMX or not Use the Up Down keys to select ON if you want to switch off the lamp via DMX or Off if you don t want this function Press Enter to confirm or Mode to cancel and return to the me...

Страница 13: ...he different wheels and other motors This can be necessary after a service or repair work For this function you have to entry the fixture code This work should be done only by authorized persons Use t...

Страница 14: ...n the display if the lamp doesn t ignite within 20 seconds The fixture will store this command and automatically ignite the lamp after 5 minutes LaeR After the ignition of the lamp was two times not s...

Страница 15: ...2 23 13 5 Color 9 UV blue fast 36 37 24 25 14 3 Color 9 Color 10 fast 38 39 26 27 15 1 Color 10 dark blue fast 40 41 28 29 15 9 Color 10 Color 11 fast 42 43 2A 2B 16 7 Color 11 cyan fast 44 45 2C 2D 1...

Страница 16: ...128 191 80 BF 50 2 74 9 Gobo rotation fast slow CCW max 1 0 turns sec 192 253 C0 FD 75 3 99 2 Audio gobo chase slow each 4 th sound impulse new gobo 254 FE 99 6 6 Gobo Audio gobo chase fast each sound...

Страница 17: ...0 02 03 02 03 1 0 1 180 04 05 04 05 1 7 1 270 06 07 06 07 2 5 PAN 2 0 08 09 08 09 3 3 2 90 10 11 0A 0B 4 1 2 180 12 13 0C 0D 4 9 2 270 14 15 0E 0F 5 7 PAN 3 0 16 17 11 11 6 5 3 90 18 19 12 13 7 3 3 18...

Страница 18: ...o Phillips screws on the bottom side of the unit 3 Release carefully the lamp holder plate from the duct where the lamp is mounted on 4 Replace the old lamp Don t touch the glass bulb of the lamp with...

Страница 19: ...light output but will also allow the fixture to function reliable throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recom mended under no circumstances should...

Страница 20: ...eaners Change the lens if it looks milky about 1 2 years For that please contact your local dealer 7 3 Cleaning the Optical System 1 Pull out the main plug 2 Wait min 20 minutes after the last operati...

Страница 21: ...rd objective Lens anti reflex Colors 11 dichroic filter plus white Gobos 10 rotating and positioning Gobos open Gobo outside diameter 25 mm image size 17 mm Gobo thickness stainless steel 0 15 mm Gobo...

Страница 22: ...nnected load 6 D DIN VDE 0711 217 6 Display 12 DMX Address 8 DMX Input 11 DMX Start address 6 E Error Messages 13 EU model 6 F Fuses 6 G Glass Gobo 17 I Injury of the retina 5 Invert 9 L Lamp type 20...

Страница 23: ...1 instruction version 0 91 GLP z German Light Production...