6 Information about the product

18

Operating and installation instructions

MiSet

0020288229_00

Information on the
data plate

Meaning

MiSet

Product designation

V

Rated voltage

mA

Rated current
Read the instructions

6.4 Serial number

You can call up the serial numbers under

MENU

INFORMATION

Serial num-

ber

. The 10-digit article number is located

in the second line.

6.5 CE marking

The CE marking shows that the products
comply with the basic requirements of the
applicable directives as stated on the de-
claration of conformity.
The declaration of conformity can be
viewed at the manufacturer's site.

6.6 Guarantee and customer

service

6.6.1 Guarantee

For information on the manufacturer's
guarantee, you can write to the contact ad-
dress that is provided on the back page
or by visiting https://self-service.glow-
worm.co.uk/warranty-registration/step-
one/.

6.6.2 Customer service

For contact details for our customer ser-
vice department, you can write to the ad-
dress that is provided on the back page, or
you can visit www.glow-worm.co.uk.

6.7 Recycling and disposal

The competent person who installed
your product is responsible for the dis-
posal of the packaging.

If the product is labelled with this

mark:

In this case, do not dispose of the
product with the household waste.

Instead, hand in the product to a collec-
tion centre for waste electrical or elec-
tronic equipment.

----- Packaging -----------------

Dispose of the packaging correctly.

Observe all relevant regulations.

6.8 Product data in accordance

with EU Ordinance no.
811/2013, 812/2013

On units with integrated weather-com-
pensated controls, including a room ther-
mostat function that can be activated, the
seasonal room-heating efficiency always
includes the correction factor for control
technology class VI. The seasonal room-
heating efficiency may deviate if this func-
tion is deactivated.

Temperature control class

VI

Contribution to the seasonal
room-heating energy effi-
ciency ɳs

4.0 %

6.9 Technical data

System

control

Rated voltage

9 to 24 V

Rated surge voltage

330 V

Pollution degree

2

Rated current

< 50 mA

Supply line cross-section

0.75 to
1.5 mm

²

IP rating

IP 20

Protection class

III

Содержание MiSet SRT 380

Страница 1: ...Operating and in stallation instructions MiSet SRT 380 GB IE...

Страница 2: ...ling the system control 15 4 Start up 17 4 1 Prerequisites for starting up 17 4 2 Running the installation assistants 17 4 3 Changing the settings later 17 5 Fault and maintenance messages 17 5 1 Faul...

Страница 3: ...IP code This product can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given su...

Страница 4: ...ns and all other ap plicable documents particu larly the Safety section and the warnings As the end user you should only carry out those activities for which these instructions provide instructions an...

Страница 5: ...ation in each zone Examples for dividing into zones Underfloor heating zone 1 and panel radiator heating zone 2 are available in one building A building is made up of several self contained residentia...

Страница 6: ...C D 18 22 20 0 4 70 60 50 40 30 15 10 5 0 5 10 15 20 A Outdoor temper ature C B Target flow tem perature C C Target room temperature C D Axis a If the heat curve 0 4 is selected and 21 C is specified...

Страница 7: ...ion 2 0020288229_00 MiSet Operating and installation instructions 7 2 9 2 Symbols Time controlled heating active Button lock active Maintenance required Fault in the heating installation Contact the c...

Страница 8: ...on behaves out side of the time period in the Set back mode function In Set back mode means Eco The heating is switched off outside of the time periods Frost protection is activated Normal The set bac...

Страница 9: ...he desired temperature for Monday Friday and Sat urday Sunday the programming applies for the time controlled Heat ing Domestic hot water and Circulation functions Overwrites the weekly planner for th...

Страница 10: ...of the temperature difference between the measured value in the system control and the value for a reference thermometer in the living room Outdoor temper ature K Comparison of the temperature differe...

Страница 11: ...it for the target flow temperature The system control compares the set value with the calculated target flow temperature and regulates to the smaller of these values Set back mode Eco The heating func...

Страница 12: ...rresponds to a modulating control system Zone Zone activated Deactivate zones that are not required All existing zones appear in the display Zone assignment Assign the system control and or remote con...

Страница 13: ...m control enables the heating function The setting Off means that the cylinder char ging time is not restricted Cyl charg anti cycl time min Setting the time period during which the cylinder charging...

Страница 14: ...ectrical installation The heating installation must be decom missioned before work is carried out on it 3 1 Selecting the lines Do not use flexible lines for power sup ply cables Use sheathed cables f...

Страница 15: ...Electrical installation set up 3 0020288229_00 MiSet Operating and installation instructions 15 3 2 Installing the system control 6 1 5 m 6 60 1 25 mm A B C 2...

Страница 16: ...3 Electrical installation set up 16 Operating and installation instructions MiSet 0020288229_00 A B 3...

Страница 17: ...sist ant switches to the basic display and the heating installation works with the values you have set 4 3 Changing the settings later All settings that you have made via the in stallation assistant c...

Страница 18: ...ss that is provided on the back page or you can visit www glow worm co uk 6 7 Recycling and disposal The competent person who installed your product is responsible for the dis posal of the packaging I...

Страница 19: ..._00 MiSet Operating and installation instructions 19 Temperature for the ball pressure test 75 Maximum permitted environ mental temperature 0 to 60 Current room air hum 35 to 95 Mode of operation Type...

Страница 20: ...Switch off the mains switch on all heat generators for approx 1 minute and then switch them on again 3 If the fault message persists inform the competent person Display Button lock activated it is not...

Страница 21: ...the heat generator this is the same power supply that feeds the system control The product is defect ive Replace the product No changes in the display can be made via the control ele ments Software er...

Страница 22: ...n the correct address to the remote control in the Zone assignment function Zone activation miss ing A zone that is in use is not yet activated In the Zone activated function select the value Yes B 3...

Страница 23: ...nes maximum length 14 Lines minimum cross section 14 Lines selecting 14 M Maintenance 17 O Operating and display functions 8 P Prerequisites for starting up the heating installation 17 Prerequisites s...

Страница 24: ...9 Technical helpline 0330 100 7679 After sales service 0330 100 3142 www glow worm co uk 0020288229_00 12 12 2019 These instructions or parts thereof are protected by copyright and may be reproduced o...

Отзывы: