2 Product description

12

Operating and installation instructions

MiSet

0020288229_00

MENU

SETTINGS

Installer level

Installation configuration

Active

Adjusting the flow temperature based on the cur-
rent room temperature.

Expan-

ded

Adjusting the flow temperature based on the cur-
rent room temperature. The system control also ac-
tivates/deactivates the zone.

The zone is deactivated: Current room temper-
ature + 2/16 K > set room temperature

Zone is activated: Current room temperature <
set room temperature - 3/16 K

The installed temperature sensor measures the current room temperature. The system con-
trol calculates a new target room temperature that is used to adjust the flow temperature.

Difference = Set target room temperature - current room temperature

New target room temperature = Set target room tempe difference

Prerequisite: In the

Zone assignment:

function, the system control and/or the remote control

is assigned to the zone in which the system control or remote control is installed.
The

Room temp. mod.:

function is ineffective if

No assignmt

is activated in the

Zone as-

signment:

function.

Control type:

2-point

Corresponds to an on/off control system

Analog.

Corresponds to a modulating control system

Zone

Zone activated:

Deactivate zones that are not required. All existing zones appear
in the display.

Zone assignment:

Assign the system control and/or remote control to the selected
zone. The system control and/or remote control must be installed
in the selected zone. The control system also uses the room
temperature sensor for the assigned unit. The remote control
uses all of the values for the assigned zone. If no zone has been
assigned to the system control and/or the remote control, the

Room temp. mod.:

function is ineffective.

Zone valve status:

Domestic hot water

Cylinder:

If there is an existing domestic hot water cylinder, the

Active

setting must be selected.

Target flow temperature: °C

Circulation pump:

Anti-legio. day:

Define the days on which you want the anti-legionella function to
run. On these days, the water temperature is increased to above
60 °C. The circulation pump is activated. The function ends after
120 minutes at the latest.
If the

Absence

function is activated, the anti-legionella function is

not carried out. As soon as the

Absence

function ends, the anti-

legionella function is carried out.

Anti-legio. time:

Define the time at which you want the anti-legionella function to
run.

Cylinder charging

hysteresis: K

The cylinder charging starts as soon as cylinder temperature <
desired temperature - hysteresis value.

Содержание MiSet SRT 380

Страница 1: ...Operating and in stallation instructions MiSet SRT 380 GB IE...

Страница 2: ...ling the system control 15 4 Start up 17 4 1 Prerequisites for starting up 17 4 2 Running the installation assistants 17 4 3 Changing the settings later 17 5 Fault and maintenance messages 17 5 1 Faul...

Страница 3: ...IP code This product can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given su...

Страница 4: ...ns and all other ap plicable documents particu larly the Safety section and the warnings As the end user you should only carry out those activities for which these instructions provide instructions an...

Страница 5: ...ation in each zone Examples for dividing into zones Underfloor heating zone 1 and panel radiator heating zone 2 are available in one building A building is made up of several self contained residentia...

Страница 6: ...C D 18 22 20 0 4 70 60 50 40 30 15 10 5 0 5 10 15 20 A Outdoor temper ature C B Target flow tem perature C C Target room temperature C D Axis a If the heat curve 0 4 is selected and 21 C is specified...

Страница 7: ...ion 2 0020288229_00 MiSet Operating and installation instructions 7 2 9 2 Symbols Time controlled heating active Button lock active Maintenance required Fault in the heating installation Contact the c...

Страница 8: ...on behaves out side of the time period in the Set back mode function In Set back mode means Eco The heating is switched off outside of the time periods Frost protection is activated Normal The set bac...

Страница 9: ...he desired temperature for Monday Friday and Sat urday Sunday the programming applies for the time controlled Heat ing Domestic hot water and Circulation functions Overwrites the weekly planner for th...

Страница 10: ...of the temperature difference between the measured value in the system control and the value for a reference thermometer in the living room Outdoor temper ature K Comparison of the temperature differe...

Страница 11: ...it for the target flow temperature The system control compares the set value with the calculated target flow temperature and regulates to the smaller of these values Set back mode Eco The heating func...

Страница 12: ...rresponds to a modulating control system Zone Zone activated Deactivate zones that are not required All existing zones appear in the display Zone assignment Assign the system control and or remote con...

Страница 13: ...m control enables the heating function The setting Off means that the cylinder char ging time is not restricted Cyl charg anti cycl time min Setting the time period during which the cylinder charging...

Страница 14: ...ectrical installation The heating installation must be decom missioned before work is carried out on it 3 1 Selecting the lines Do not use flexible lines for power sup ply cables Use sheathed cables f...

Страница 15: ...Electrical installation set up 3 0020288229_00 MiSet Operating and installation instructions 15 3 2 Installing the system control 6 1 5 m 6 60 1 25 mm A B C 2...

Страница 16: ...3 Electrical installation set up 16 Operating and installation instructions MiSet 0020288229_00 A B 3...

Страница 17: ...sist ant switches to the basic display and the heating installation works with the values you have set 4 3 Changing the settings later All settings that you have made via the in stallation assistant c...

Страница 18: ...ss that is provided on the back page or you can visit www glow worm co uk 6 7 Recycling and disposal The competent person who installed your product is responsible for the dis posal of the packaging I...

Страница 19: ..._00 MiSet Operating and installation instructions 19 Temperature for the ball pressure test 75 Maximum permitted environ mental temperature 0 to 60 Current room air hum 35 to 95 Mode of operation Type...

Страница 20: ...Switch off the mains switch on all heat generators for approx 1 minute and then switch them on again 3 If the fault message persists inform the competent person Display Button lock activated it is not...

Страница 21: ...the heat generator this is the same power supply that feeds the system control The product is defect ive Replace the product No changes in the display can be made via the control ele ments Software er...

Страница 22: ...n the correct address to the remote control in the Zone assignment function Zone activation miss ing A zone that is in use is not yet activated In the Zone activated function select the value Yes B 3...

Страница 23: ...nes maximum length 14 Lines minimum cross section 14 Lines selecting 14 M Maintenance 17 O Operating and display functions 8 P Prerequisites for starting up the heating installation 17 Prerequisites s...

Страница 24: ...9 Technical helpline 0330 100 7679 After sales service 0330 100 3142 www glow worm co uk 0020288229_00 12 12 2019 These instructions or parts thereof are protected by copyright and may be reproduced o...

Отзывы: