0020154078_00 - 02/13 - Glow-worm
4
SAFETY
∙
Welding is to be carried out with nitrogen and the circuit’s
air-tightness is to be tested under pressure, with nitrogen.
∙
Re
fi
lling must be done at the liquid phase.
∙
In case of leakage, do not add
fl
uid: drain the remaining
fl
uid from the circuit and eliminate, in accordance with the
applicable regulations.
∙
Create a vacuum in the circuit with a maximum pressure of
10 mbar (10 x 10
2
Pa) (static pressure).
∙
Bleed the circuit before any welding work.
∙
Comply with the values given in chapter 10 when charging
with refrigerant.
1.5 Intended
use
The product is a state-of-the-art product which has been
constructed in accordance with recognised safety regulations.
Nevertheless, there is still a risk of injury or death to the user
or others or of damage to the product and other property in
the event of improper use or use for which it is not intended.
The heat pump is a air -water system which heats all types of
buildings by using the energy contained in the outside air.
The system enhances the recuperated energy so that it can
be utilized by traditional heating (heating
fl
oor and/or low-
temperature radiators).
The heat pump cannot be used without its control box
Systempro.
Intended use includes the following:
- observing the included operating, installation and
maintenance instructions for this product and any other
parts and components of the system
- installing and
fi
tting the product in accordance with the
product and system approval
- complying with all of the inspection and maintenance
conditions listed in the instructions.
Any other use than the use described in the instructions at
hand or any use extending the described use is not intended.
Any direct commercial or industrial use is also deemed to be
improper.
Any unintended use is prohibited.
1.6
Rules and regulations
On installing and commissioning the appliance you must
adhere to the technical rules, standards and provisions in
e
ff
ect at the time.
1.7 CE
label
The CE mark indicates that the products described in these
instructions are in compliance with the following directives:
- Directive 2006/95/EC of the Council with amendments
"Directive Concerning Electrical Equipment for Use Within
Speci
fi
c Voltage Limits" (Low voltage directive)
- Directive 2004/108/EC of the Council with amendments
"Directive Concerning Electromagnetic Compatibility"
- Directive 97/23/EEC of the Council with amendments
"Directive Concerning pressure equipment"
- Directive 2007/1494/EC of the Council with amendments,
dated December 17, 2007, determining, in accordance with
Directive 2006/842/EC of the Council with amendments,
the label type and the additional requirements as regards
the labelling of products and equipment containing certain
fl
uorinated greenhouse e
ff
ect gas.
- Directive 2006/842/EC of the Council with amendments
of May 17, 2006 on certain
fl
uorinated greenhouse gasses
(OJEU of June 14, 2006)
1.8 Approvals
This product has been fully tested in accordance with:
- BS EN 14511:2011
1.8.1 Local
regulations
Benchmark places responsibilities on both
manufacturers and installers. The purpose is to
ensure that customers are provided with the correct
equipment for their needs, that it is installed,
commissioned and serviced in accordance with the
manufacturer’s instructions by a competent person
approved at the time by the Health and Safety
Executive and that it meets the requirements of the
appropriate Building Regulations.
The Benchmark Checklist can be used to demonstrate
compliance with Building Regulations and should be
provided to the customer for future reference.
Installers are required to carry out installation,
commissioning and servicing work in accordance with
the Benchmark Code of Practice which is available
from the Heating and Hotwater Industry Council who
manage and promote the Scheme.
∙
Visit www.centralheating.co.uk for more information.