5 Troubleshooting

12

Operating instructions ENERGY ..s 0020200965_02

Conditions

: Temperature controlled by the control-

ler, with heating mode activated

Set the maximum heating flow temper-
ature on the boiler (

Page 12).

Set the room temperature on the con-
troller.

The actual heating flow temperature
is set automatically by the controller.

Conditions

: Outside temperature sensor connected

to the boiler, with heating mode activated

When you press the

,

or

but-

ton.

The display shows the heating flow
temperature calculated by the boiler.

The actual heating flow temperature
is set automatically by the boiler.

4.8 Product settings

Note

The sequence in which the avail-
able settings are shown depends
on the operating mode selected.
If the

Domestic hot water + Heat-

ing

operating mode is selected,

the hot water temperature must be
confirmed in order to set the flow
temperature of the heating.

1. Press the

or

button to set the tem-

perature.

2. Press the

button to confirm.

4.9 Switching the product to

standby mode

Press the

button for less than three

seconds.

Once the requirement currently in
use has finished, the display will
show

OFF

and go out.

The product is now in standby mode.

The product's frost protection func-
tion is activated.

The main power supply is not inter-
rupted. The product continues to be
supplied with power.

5 Troubleshooting

5.1 Detecting and rectifying faults

If problems occur whilst operating the
product, you can carry out certain self-
checks with the aid of the table in the
appendix.
Troubleshooting (

Page 14)

If the product still does not function
without problems after the checks have
been carried out using the table, con-
tact your competent person to rectify
the problem.

5.2 Fault codes in the display

Fault codes have priority over all other dis-
plays. If several faults occur at the same
time, the corresponding codes are dis-
played alternately for two seconds each.

If your product displays a fault code
(F.xx), contact a competent person.

6 Care and maintenance

6.1 Maintenance

An annual inspection of the product carried
out by a competent person is a prerequis-
ite for ensuring that the product is perman-
ently ready and safe for operation, reliable,
and has a long working life.

6.2 Caring for the product

Caution.
Risk of material damage
caused by unsuitable clean-
ing agents.

Do not use sprays, scouring
agents, detergents, solvents
or cleaning agents that con-
tain chlorine.

Содержание ENERGY 12s -A

Страница 1: ...The energy you need Operating instruc tions ENERGY s ENERGY 12s A H GB ENERGY 15s A H GB ENERGY 18s A H GB ENERGY 25s A H GB ENERGY 30s A H GB GB IE...

Страница 2: ...Checking the heating system pressure 10 4 4 Filling the heating installation 11 4 5 Selecting the operating mode 11 4 6 Setting the hot water temperature 11 4 7 Setting the heating flow temperature 1...

Страница 3: ...ing installations and for hot wa ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance with...

Страница 4: ...void rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains...

Страница 5: ...ake any changes The product itself to the gas air water and electricity supplies to the entire flue gas install ation to the entire condensate drain system to the expansion relief valve to the drain p...

Страница 6: ...design instructions Do not fit the casing on the product yourself If you require cabinet type casing for the product consult an approved heating special ist company 1 3 11 Risk of material damage cau...

Страница 7: ...stic heating and hot water systems in the UK and to en courage regular servicing to optimise safety efficiency and performance Benchmark is managed and promoted by the Heating and Hotwater Industry Co...

Страница 8: ...densing technology Efficiency class of the boiler in accordance with EC Dir ective 92 42 EEC Type Xx3 x Permissible flue gas connec tions PMS Maximum water pressure in heating mode PMW Maximum water p...

Страница 9: ...ning Heating mode Permanently on Heating mode activated Flashing Burner on in heating mode Display flashing Switching on the product Fault Setting confirmed Fault in the product Appears instead of the...

Страница 10: ...water valve and see whether water is escap ing there 4 1 2 Switching on the product Switch on the product via the main switch installed on site 4 2 Basic display The filling pressure in the heating in...

Страница 11: ...Fill with water until the required filling pressure is reached 4 Check the filling pressure in the display 5 Close the filling cock after filling 4 5 Selecting the operating mode Note The unit is alw...

Страница 12: ...d the display will show OFF and go out The product is now in standby mode The product s frost protection func tion is activated The main power supply is not inter rupted The product continues to be su...

Страница 13: ...cold water stop cock 7 2 Permanently decommissioning the product Have a competent person permanently decommission the product 8 Recycling and disposal The competent person who installed your product i...

Страница 14: ...e building The product switches on automat ically when the power is restored The product is switched off Switch on the product The heating flow temperature is set too low or to the Heating off positio...

Страница 15: ...e fault persists and you have pressed the fault clearance key once more a burner anti cycling time of 45 minutes is automatically activated The display shows S 54 If the fault persists consult a compe...

Страница 16: ...639 Technical helpline 0330 100 7679 After sales service 0330 100 3142 www glow worm co uk 0020200965_02 21 10 2016 These instructions or parts thereof are protected by copyright and may be reproduced...

Отзывы: