Appendix
42
Installation and maintenance instructions MicraCom 0020289288_02
Code
Parameter
Values
Unit
Increment, select, explanation
Factory
setting
Min.
Max.
d.31
Automatic filling device
0
2
–
0 = Manual
1 = Semi-automatic
2 = Automatic
0
d.33
Fan speed target value
Current value
rpm
Fan speed = Display value x 1000
–
d.34
Value for the fan speed
Current value
rpm
Fan speed = Display value x 1000
–
d.35
3-port valve position
Current value
–
0 = Heating
40 = Mid-position (frost protection or filling)
Hi
= Domestic hot water
–
d.36
Value for the domestic
hot water flow rate
Current value
l/min
–
–
d.39
Water temperature in the
solar circuit
Current value
℃
The water temperature in the solar circuit is then
only displayed if an optional solar set has been in-
stalled.
–
d.40
Heating flow temperature
Current value
℃
–
–
d.41
Heating return temperat-
ure
Current value
℃
–
–
d.43
Heat curve
0.2
4
K
Consult the accessory's operating instructions in
order to implement this setting.
1.2
d.45
Base point of the heat
curve
15
30
℃
Consult the accessory's operating instructions in
order to implement this setting.
20
d.47
Outdoor temperature
Current value
℃
–
–
d.50
Correction of the min-
imum fan speed
0
2500
rpm
Increment = 100
Fan speed = Display value x 1000
600 (0.6 x
1000)
d.51
Correction of the max-
imum fan speed
-2500
0
rpm
Increment = 100
Fan speed = Display value x 1000 (flashing)
-1000 (1.0 x
1000)
d.58
Solar circuit reheating
0
3
–
Applies to: Installed solar set (optional)
0 = Product's anti-legionella function deactivated
3 = Domestic hot water activated (min. target value
55 °C)
0
d.60
Number of blocks by the
temperature cut-out (limit
temperature)
Current value
–
If the value is greater than 99, the display shows the
number alternately.
Example using the number 1581: The display re-
peatedly shows the sequence 15
→
81
→
__.
–
d.61
Number of unsuccessful
ignitions
Current value
–
–
d.62
Day/set-back function
0
30
K
Increment = 1
0
d.64
Average burner ignition
time
Current value
s
–
–
d.65
Maximum burner ignition
time
Current value
s
–
–
d.67
Remaining burner anti-
cycling time (setting un-
der d.02)
Current value
min
–
–
d.68
Number of unsuccessful
ignitions at 1st attempt
Current value
–
If the value is greater than 99, the display shows the
number alternately.
Example using the number 1581: The display re-
peatedly shows the sequence 15
→
81
→
__.
–
d.69
Number of unsuccessful
ignitions at 2nd attempt
Current value
–
–
d.71
Maximum target heating
flow temperature
30
75
℃
Increment = 1
75
d.77
Maximum post-heating
output for the domestic
hot water cylinder
–
–
kW
Increment = 1
–
d.80
Running time in heating
mode
Current value
h
Running time = Display value x 1000
–
d.81
Running time in domestic
hot water mode
Current value
h
Running time = Display value x 1000
–
d.82
Number of burner igni-
tions in heating mode
Current value
–
Number of ignitions = Display value x 1000
–