7 Installation
22
Installation and maintenance instructions MicraCom 0020289288_02
7.9.1
Removing the front casing
2x1
D
B
C
A
7.9.2
Opening the electronics box
A
B
B
7.9.3
General information about connecting
cables
Caution.
Risk of material damage caused by incor-
rect installation.
Mains voltage at incorrect terminals and plug
terminals may destroy the electronics.
▶
Do not connect any mains voltage to the
eBUS terminals (+/-).
▶
Only connect the connection cable to the
terminals marked for the purpose.
230V
24V / eBUS
1.
Route the connection cable in the cable trunking on the
underside of the product.
2.
Ensure that the grommet is plugged in correctly and
that the cables have been routed correctly.
3.
Ensure that the grommets envelop the connection
cables tightly and with no visible gaps.
4.
Use the strain reliefs.
5.
If required, shorten the connection cables.
-
+
N
L
PE
30 mm
≤
30 mm
≤
40 mm
≤
6.
Strip the flexible line as shown in the figure. In doing so,
ensure that the insulation on the individual conductors
is not damaged.
7.
Only strip inner conductors just enough to establish
stable connections.
8.
To avoid short circuits resulting from loose individual
wires, fit conductor end sleeves on the stripped ends of
the conductors.
9.
Screw the respective plug to the connection cable.
10. Check whether all conductors are inserted mechanic-
ally securely in the plug terminals. Remedy this if ne-
cessary.
11. Plug the plug into the associated PCB slot.