Regulations

When installing and commissioning the control, the regulations below shall 

be observed in their current version.

The electrical installation must be installed by a 

competent person

 and in 

accordance with the relevant standards.

All wiring to current I.E.E. wiring regulations.

In GB, this is BS 7671.

In IE, this is the current edition of ETCI rules.

Where no specific instructions are given, reference should be made to the 

relevant British Standard Code of Practice.

Where no British Standard exists, materials and equipment should be fit for 

their purpose and of suitable quality and workmanship.

The installation of this appliance must be carried out by a 

competent 

person

 in accordance with the rules in force in the countries of destination. 

Manufacturer’s instructions must not be taken as overriding statutory 

requirements.

Technical data

80

80

23

30

96

96

Dimensions

13549

Diagram 4

Climastat Room Thermostat installation

Remove the front cover from the Climastat respecting the order of 

operations (A) to (C), refer to diagram 5.

5 Installation and Servicing

Setting knob

13579

Diagram 5

A

C

C

B

Fixing to the wall

Fit the Climastat back box to the wall, refer to diagram 6.

Choose the location of the Climastat. See section “Appliance location”.

Climastat back box fitting

13580

Diagram 6

Electrical connection

Warning:

 Isolate the boiler from the electrical supply. 

A skilled professional should make the electrical connections.

Use a 2 core connection cable that complies with the specifications given in. 

(“Technical data”).

Important:

 If the cable is greater than 10 metres, separately insulate EBUS 

and high voltage cables to avoid electrical interference.

Route the cable between the Climastat room thermostat and the electrical 

cartridge on the boiler. Connect the cable to the terminal connection in the 

Climastat. Polarity is not important, refer to diagram 7.

Connect the cable to the EBUS connection in the electrical cartridge at the 

boiler. Polarity is not important, refer to diagram 8.

Climastat cable connection

13581

Diagram 7

Boiler cable connection

Diagram 8

 

 

13586

6 Commissioning

IMPORTANT

• As supplied the operating mode of this control is ON/OFF as per a 

conventional room thermostat ( the boiler will modulate to achieve the flow 

temperature selected on the boiler as per conventional boiler operation).

• The modulating operating mode must be selected before this control will 

modulate the temperatures of the radiators to achieve the room temperature 

set point.

• The modulating operating mode must not be selected if this control is used 

with a heating only appliance that heats DHW via an external cylinder/store.

Put the boiler into operation.

Installation Menu Adjustments

1. Press the setting knob for 10 seconds to access the setting menu.

2. When “0” appears, turn the setting knob up to “96” on the display.

3. Confirm by pressing the setting knob.

N.B. If outdoor sensor is attached, the menu option “1” is not available.

If outdoor sensor  is not attached, menu option “2” is not available.

When first menu “1” appears, press knob to select menu “2”.

Press the setting knob to go to next menu (see table 1).

The settings in both menus can be changed by turning the knob.

To confirm all settings, press setting knob for 5 seconds.

The display will return to normal setting after 1 minute or after pressing the 

setting knob for 5 seconds. 

Table 1

13583

Menu  Title

Action / Information

1

Selecting 

appliance

mode

Choose a value :

0 = non modulating 

 On/Off mode (factory

 

setting) Utilises user defined flow temp setpoint, 

NOT factory default, if different.

1 = modulating 

automatic calculation of the 

heating setting. Note: Must NOT be put in

modulating mode if used on heating only

appliance that indirectly heats domestic hot

water via an external cylinder/store.

2

Selecting the 

heating

curve (*)

Choose a value between 0.2 and 4. (factory 

setting : 1.2)

Refer to the manual for the outside sensor 

connected to the boiler to carry out this 

adjustment.  Comment: the adjustments made 

to the outside sensor on the boiler will no 

longer be active.

If outdoor sensor is attached, menu option "1" is not available.

If outdoor sensor is not attached, menu option "2" is not available.

Control / Commissioning

Start the Climastat according to the indications of the operating instructions 

and check whether it runs.

Check the whole control and safety devices, their setting and their 

operation.

User information

Explain to the user the Climastat operating principles and demonstrate.

Look at the operating instructions together and answer any questions.

Give the user all the manuals and documents concerning the appliance and 

tell the user to keep them near the Climastat / Boiler.