These instructions consist of, Instructions for Use, Installation, Servicing and Fault 

Finding. The instructions are an integral part of the appliance and must, to comply with 

the current issue of the Gas Safety (Installation and Use) Regulations, be handed to the 

user on completion of the installation.

General and Sales enquiries: 

Tel.    01773 824639    

Fax:   01773 820569

Technical Helpline:

 

01773 828300

        CONTENTS                 DESCRIPTION 

               SECTION   

General

 

1

Documents 

 

Appliancation

 

 

Servicing

 

 

Recycling

 

 

 

 

Setting knob description 

 

Setting the room temperature 

 

Setting the domestic hot water 

 

Fault finding

 

  

Frost protection 

 

Appliance location 

 

Safety instructions and regulations  

 

Regulations 

4

Technical data 

 

Climastat Room Thermostat installation 

 

Fixing to the wall 

 

Electrical connection 

 

Adjustment 

 

Control / Commissioning 

 

User information 

 

General

Information

Instructions

for Use

User

Fault Finding and 

Frost Protection

Installer Important 

Information

Installation

and

Servicing

Commissioning

General

Climastat is a room thermostat that gives you personalised heating comfort 

according to your needs and enhances the energy efficiency of your heating 

system. The modulating regulation built into this thermostat changes the 

temperature of the radiators to suit the desired ambient temperature.

Documents

Please keep these instructions as well as any documents enclosed with it, 

safe for future reference.

We accept no liability in case of damage due to the non-compliance of 

these instructions.

Application

The Climastat room thermostat controls a heating appliance depending on 

the room temperature.

Any other use is considered as inappropriate and is forbidden.

The manufacturer shall not be responsible for any damage caused by 

another use. In that case the user shall be responsible.

Servicing

Clean the case of the Climastat with damp soapy cloth.

Make sure that no water goes inside the Climastat.

Do not use any abrasive cleaning products as they could damage the 

housing or plastic case.

Recycling

The Climastat comprises many recyclable parts.

The packaging, the Climastat and the content of the package shall not 

be thrown together with domestic waste but disposed of according to the 

current regulations.

1 General Information

2 Instructions for Use

Front cover

13543

Diagram 1

Description of display

13735

Diagram 2

Setting knob description 

Turn setting knob anti-clockwise (A) to adjust setting downward.

Turn setting knob clockwise (B) to adjust setting upward.

To access or confirm a setting, press the knob (C).

Setting the room temperature 

Turn the setting knob to adjust to the desired room temperature once and 

the set temperature will flash.

The setting is saved automatically after 5 seconds and the main screen is 

displayed.

Setting the domestic hot water temperature    

 

(for combination boilers only)   

Press the setting knob.

Turn the setting knob once to adjust to desired hot water temperature and 

the set temperature will flash. Press the knob again to confirm the new 

temperature or the setting is saved automatically after 5 seconds. The set 

temperature flashes.

3 User Fault Finding and Frost Protection

Fault finding

In the event of an anomaly, the Climastat displays error messages on the 

display.

Warning:

Never try to service or repair the Climastat by yourself and only start the 

Climastat once a skilled professional has repaired the fault.

 

4 Installer Important Information

Appliance location

Do not install the Climastat above another appliance that could damage it, 

for example, above a cooker that might emit steam or grease or in a room, 

which has a lot of dust in the atmosphere which is corrosive.

The Climastat must be installed in a room protected from freezing 

temperatures. Take the necessary precautions.

Install the Climastat in such a manner so as to guarantee optimum 

measurement of the ambient temperature by positioning it on an inside wall 

in the main room of the house, approximately 1.5 metres from the ground.

Do not install the Climastat near heat sources such as radiators, televisions, 

sunlight, on cold walls, between furniture, behind curtains, or other objects 

that could effect measurement of ambient air temperature in the room. 

Do not install close to draughts of air that could come from doors or 

windows.

Explain these requirements to the home owner.

Safety instructions and regulations

This Climastat is tested and certificated for safety and performance. It is, 

therefore, important that no alteration is made to the Climastat, without 

permission, in writing, from Glow-worm.

Any alteration not approved by Glow-worm, could invalidate the certification, 

appliance warranty and may also infringe the current issue of the statutory 
requirements.

Warning:

Incorrect installation can cause electric shock or

appliance damage. Protect all the electrical components from water when 

you carry out any work.

Setting knob

13545

Diagram 3

Frost protection

The frost protection system activates the boiler when the ambient 

temperature in the room where the Climastat is installed falls below 3°C. 

The outside temperature falls below 5°C (protection possible only if an 

outside sensor is connected to the boiler).

If you leave home for a long period, consult the boiler manual.

0020041169-04