![Glow-worm Betacom2 24 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/glow-worm/betacom2-24/betacom2-24_installation-and-servicing_2234493039.webp)
0020145065_01 - 09/12 - Glow-worm
17.8 Combustion block
10
11
12
13
14
15
16
17
1
2
4
3
5
6
7
8
9
Legend
1 Gas valve connection
2 Grounding cable
3 Spark electrode inlet
4 Spark electrode retaining screw.
5 Spark electrode gasket
6 Spark electrode
7 burner retaining nut
8 Burner retaining screw
9 Thermal fuse connection
10 Coil
11 Heat exchanger
12 burner door seal
13 burner
14 Gas valve
15 fan
16 fan connection
17 Gas pipe
17.8.1
Spark electrode
•
Disconnect the electrode inlet (3) and the grounding cable (2).
•
Remove the 2 spark electrode retaining screws (4).
•
Carefully remove the electrode from the combustion chamber.
•
Check that the extremes of the electrode (6) are not damaged.
•
Clean away any accumulation of dirt and check that the
distance between the two electrodes is between 3.5 and 4.5
mm.
•
Check that the gasket (5) is not damaged. Replace if necessary.