Gas Category
This boiler is for use only on G20 natural gas, but may be
converted for use on G31 gas (Propane L.P.G.).
Gas Safety (Installation and Use) Regulations
In your own interests and that of safety, it is the Law that ALL
gas appliances are installed by
competent person
approved
at the time by the Health and Safety Executive in accordance
with the current issue of the above regulations.
Control of Substances Hazardous to Health
Under Section 6 of The Health and Safety at Work Act
1974, we are required to provide information on substances
hazardous to health.
The adhesives and sealants used in this appliance are cured
and give no known hazard in this state.
Insulation Pads / Ceramic Fibre
These can cause irritation to skin, eyes and the respiratory
tract.
If you have a history of skin complaint you may be susceptible
to irritation. High dust levels are usual only if the material is
broken.
Normal handling should not cause discomfort, but follow
normal good hygiene and wash your hands before eating,
drinking or going to the lavatory.
If you do suffer irritation to the eyes or severe irritation to the
skin seek medical attention.
Manual Handling
With regards to the “Manual Handling Operations, 1992
Regulations”, it should be noted that each appliance module
exceeds the recommended weight for a one person lift.
The handling of the boiler may involve lifting, pushing and
pulling, the use of a sack truck may be required.
The following handling techniques and precautions should be
considered:
- Grip the boiler at its base
- Be physically capable
- Use safety clothing where appropriate, e.g. gloves, safety
footwear.
Ensure safe lifting techniques are used
- Keep back straight.
- Avoid twisting at the waist.
- Avoid upper body/top heavy bending.
- Always grip using the palm of the hand.
- Use designated hand holds.
- Keep load as close to body as possible.
- Always use assistance if required.
Electrical Supply
The electrical installation must be installed by a
competent
person
approved at the time by the Health and Safety
Executive
and in accordance with the relevant standards.
The boiler and immersion heater must be earthed.
All system components shall be of an approved type and all
wiring to current I.E.E. wiring regulations.
External wiring must be correctly earthed, polarised and in
accordance with the relevant standards.
In GB this is BS 6891.
In IE this is the current edition of I.S.813 “Domestic Gas
Installations”.
The boiler must be connected to a permanent 230V ac, 50Hz
supply.
Connection of the whole electrical system of the boiler,
including any heating controls, to the electrical supply must
be through one common isolator and must be fused 3 Amp
maximum.
Isolation should be by a double pole switched fused spur box,
with a minimum gap of 3mm for both poles. The fused spur
box should be readily accessible and preferably adjacent to
the appliance. It should be identified as to its use.
Alternatively connection can be made through an unswitched
shuttered socket and 3A fused 3-pin plug both to the current
issue of BS 1363 may be used, provided they are not used in
a room containing a bath or shower.
Wiring to the boiler must be PVC 85
O
C insulated cable, not
less than 0.75mm
2
(24/0.20mm).
Immersion Heater -
a thermostatically controlled immersion
heater with manual reset is fitted to the cylinder as a back
up for domestic hot water in the event of the boiler being
inoperable. The immersion heater
MUST
be wired separately
using 3kW 13amp wiring and in accordance with the relevant
standards.
Important Information
WARNINGS
Gas Leak or Fault
Turn off the gas emergency control valve immediately. Eliminate all sources of ignition, i.e.smoking,
blowlamps, hot air guns etc.
Do not operate electrical lights or switches either on or off. Open all doors and windows, ventilate the area.
Metal Parts
This boiler contains metal parts (components) and care should be taken when handling and cleaning,
with particular regard to edges.
Sealed Components
Under no circumstances must the User interfere with or adjust sealed parts.
Содержание 100sxi
Страница 8: ...Supplied By www heating spares co Tel 0161 620 6677 8 1 Boiler Specifications 13247 Diagram 1 1 ...
Страница 9: ...Supplied By www heating spares co Tel 0161 620 6677 9 Diagram 1 2 13290 1 Boiler Specifications ...
Страница 52: ...Supplied By www heating spares co Tel 0161 620 6677 52 14 Fault Finding 13412 Diagram 14 4 Fault Codes ...
Страница 70: ...Supplied By www heating spares co Tel 0161 620 6677 70 17 Declaration of Conformity ...
Страница 71: ...Supplied By www heating spares co Tel 0161 620 6677 71 Notes ...