Set-up 4
0020283671_03 Energy 2 Installation and maintenance instructions
9
Number
Designation
1
Filling device
2
Connection pipe (heating flow and return)
1
Cold water connection pipe
1
Domestic hot water connection pipe
1
Gas pipe
1
Expansion relief valve drain pipe
1
Mounting template
1
Enclosed documentation
4.4
Dimensions
96
121
34
123
185
390
123
58 58
170
702
150
280
1
2
3
4
5
7
6
1
Heating flow
2
Domestic hot water
connection
3
Gas connection
4
Cold water connection
5
Heating return
6
Connection on the rear
of the air/flue pipe
7
Connection on the top
of the air/flue pipe
4.5
Minimum clearances
C
C
A
B
D
Minimum clearance
A
150 mm (top air/flue gas connection)
20 mm (air/flue gas connection on the rear)
B
150 mm
C
5 mm
(70 mm if the side sec-
tions ought to be removed)
D
600 mm
It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances.
4.6
Using the mounting template
▶
Use the mounting template to ascertain the locations at
which you need to drill holes.
4.7
Wall-mounting the product
Note
If you are using the rear air/flue connection, in-
stall the air/flue pipe before you wall-mount the
product.
1.
Check whether the wall has sufficient load-bearing ca-
pacity to bear the operating weight of the product.