CARE, MAINTENANCE AND DISPOSAL

Recommendations for maintenance and use of the Globus Electrostimulator:

In case of damage to the instrument's exterior, this must be replaced before using the elec-

trostimulator again.

In case of presumed or real failure, do not open the instrument or attempt to make repairs

yourself.  Repairs may only be made by an authorized service center .  

Protect the electrostimulator from violent blows, shaking and overturning, which may damage

the instrument and lead to malfunction in the long term even though no immediate failure is
apparent.  

Protect the electrostimulator from splashes of water, heat sources, dust, humidity, direct expo-

sure to sunlight and strong magnetic fields.  The instrument should not be used when wrapped
or covered.

Do not clean the instrument with solvents such as paint thinner, gasoline, kerosene, alcohol

and other chemicals.  Clean the instrument and cables with a soft cloth dampened with water.  

Prior to using the instrument after a long period of disuse, check that the electrostimulator and

the battery are functioning correctly (contact an authorized service center).  

Do not use the instrument while the batteries are being charged.

The electrostimulator is connected to the electrical line through its own power supply. Before

attaching the electric current, be sure that your electrical system conforms to national stan-
dards. 

Do not use the electrostimulator together with other electronic equipment, above all those

used to support vital functions.

Store in the supplied carrying case in conditions of 20%-85% relative humidity and 5°-45° C.

Recommendations for maintenance and use of electrodes and cables:

Clean and dry the skin prior to attaching the electrodes to ensure good conductivity.

- The electrodes are designed to be used for 25-30 applications on a single person. 
- After using the single-user, reusable electrodes, protect the adhesive with the supplied film
and store them in a sealed, clean plastic bag.  Do not permit the electrodes to attach to each
other. 
- Do not use cables or electrodes that show signs of wear or are not perfectly adherent to the
skin.  Discard them and obtain manufacturer's original replacement 

parts.

- If you use electrodes that are not self-adhering , clean the surface with water before use. 
- Store in the supplied carrying case in conditions of 20%-85% relative humidity and 

5°-45° C.

Recommendations for disposal 

- Do not burn.
- Dispose of the instrument according to national rules for the elimination of electronic instru-
ments.

PRECAUTIONARY MEASURES

 -The electrostimulator should only be used by mentally competent adults.
 -Keep the instrument out of the reach of children.
 -The electrostimulator should not be used for purposes other than neuromuscular stimulation as

described in this manual. 

 -The electrostimulator must be used according to the instructions in this manual  and under the

continued supervision of a physician or a physical therapist.  

 -Do not use the electrostimulator without first consulting your physician regarding any health

problems.  

 -The electrostimulator should only be used with the supplied skin electrodes  intended for neu-

romuscular stimulation.

7

WARNINGS

REV.  03.09.04

Содержание Genesy 500

Страница 1: ...ELECTROSTIMULATORS Genesy 500 USER MANUAL Rev 03_09 04 0476...

Страница 2: ...33 www globusitalia com info globusitalia com This product has been manufactured according to the technical regulations in force and is certified according to Directive 93 42 EEC for medical devices b...

Страница 3: ...Executed AUTO STIM Automatic Favorites 2 2 Mode simultaneous stimulation 15 PROGRAMMING MENU 16 Create a new program Modify an existing program Eliminate a program ADVANCED MENU 17 INTENSITY OF STIMU...

Страница 4: ...IST INCONTINENCE 25 DIAGNOSTICS 25 Rheobase calculation Chronaxie calculation Slope calculation PROGRAMS LIST DENERVATED 26 ELECTRODE PLACEMENT 27 WARRANTY TERMS 35 FREQUENTLY ASKED QUESTIONS 35 REV 0...

Страница 5: ...resent If any material is missing please contact your retailer immedia tely Please also check the integrity of the stimulator and the supplied electrodes and cables Electrodes The supplied electrodes...

Страница 6: ...bus Electrostimulator be used with caution in persons with capil lary fragility to avoid excessive capillary damage Potential adverse effects Skin irritation may occur in persons with particularly sen...

Страница 7: ...vital functions Store in the supplied carrying case in conditions of 20 85 relative humidity and 5 45 C Recommendations for maintenance and use of electrodes and cables Clean and dry the skin prior t...

Страница 8: ...r the following purposes Pain treatment in general Any type of sequential electrostimulation Aesthetic care Sports training The Electrostimulator may be used with or without the supervision of physici...

Страница 9: ...ates To charge the batteries turn off the electrostimulator and detach the electrodes Attach the supplied battery charger by inserting the plug in the appropriate inlet on the electrostimulator figure...

Страница 10: ...lored cables for EMS and TENS programs Use channels 1 and 3 with the gray cables for the Microcurrents MCR program Use channels 1 and 3 with the colo red cables for the Denervated Muscles program with...

Страница 11: ...s selection 3 during a program Return to the previous phase DOWN DEL Move the selection down During a program simultaneously decrease the intensity of the 4 chan nels TIME During a program displays th...

Страница 12: ...ried out before the message EMPTY appears proceed to the Program List Program selection from the Program List menu Use the UP and DOWN keys to position the cursor on Program List and confirm by press...

Страница 13: ...m press OK Resumption after a pause repeats the last interrupted cycle Stop a program If you need to stop a program before its end switch off the instrument by pressing the OK key for 3 seconds Visual...

Страница 14: ...y execution Registration in memory occurs automatically at the end of any program when the memory is full older programs are automatically deleted To recall a program in memory position the cursor on...

Страница 15: ...ect the program for channels 3 and 4 Use the UP and DOWN keys to select the area of the second program channels 3 and 4 and confirm with OK 6 Use the UP and DOWN keys to select Man or Woman for the se...

Страница 16: ...s display The following parameters are set sequentially Step 1 Type of stimulation After inserting the name of the new program use the UP and DOWN keys to select the desired type of stimulation by cho...

Страница 17: ...up area and allows the duration of back lighting in stand by mode to be varied using the Up and Down keys Contrast FUNCTION The Contrast function present inside the Set up menu allows the level of co...

Страница 18: ...uscle is contracted maximally This is intense treatment that should be performed only only after having carried out various applications at lower intensity In the descriptions of the various treatment...

Страница 19: ...program may offer more than one difficulty level or body area to exercise PROGRAMS LIST PAIN ANTALGIC Endorphinic Tens Contracture Sciatica Lumbago Cervical pain Periathritis S O Epicondylitis Carpal...

Страница 20: ...rou tes of the pain Against every kind of pain It can be used every time you need to relieve pain Warning TENS pro grammes relieve pain but do not eli minate its cause If it persists see the doc tor O...

Страница 21: ...timulator automatically brings the intensity to the correct level This value should not be altered during execution of the program The Microcurrents programs cannot be run in the 2 2 mode with other t...

Страница 22: ...t with metallic items e g tables and chairs Use of iontophoresis programs The duration of iontophoresis programs is automatically set for 10 min Once the program has started it is possible to modify t...

Страница 23: ...equelae of fractu res myalgia osteoarthrosis Thiomucase Lumbago cervical pain cellulitis Sodium Chloride Sclerotic and softener Use with low intensity current Calcium Chloride Increase cal cium conten...

Страница 24: ...aproxen Dioxilase Orudis ketoprofen Dicloreum diclofenac Tantum benzydamine Dievril Xylocaine lidocaine Essaven gel Fastum gel ketoprofen Flectadol lysine acetylsalicylate Fibrase pentosan polysulfate...

Страница 25: ...des it relates to the contractile value of the muscle and to its trophism Chronaxie calculation The instrument automatically selects a value of intensity twice that of the rheobase The ampli tude of t...

Страница 26: ...of the impulse and duration of the rest period Triangular currents These currents reach a maximal value of intensity with a linear ramp that combined with impul ses of rather long duration causes a c...

Страница 27: ...OF ARM BICEPS BRACHII 2 TRICEPS MUSCLE OF ARM TRICEPS BRACHII 3 WRIST AND FINGER EXTENSORS 5 DELTOID MUSCLE 4 WRIST AND FINGER FLEXORS 6 DELTOID MUSCLES ANTERIOR Work position Work position Work posit...

Страница 28: ...STERIOR 8 GREATER AND SMALLER PECTORAL MUSCLES 9 BREAST 12 10 MUSCULUS LATISSIMUS DORSI 11 TRAPEZIUS MUSCLE Work position Work position Work position Work position Work position Work position MUSCULUS...

Страница 29: ...ition Work position Work position Work position Work position Work position MUSCULUS RECTUS ABDOMINIS MUSCULUS LATISSIMUS DORSI AND MUSCULUS ILEOCOSTAL THORACIS MUSCULUS RECTUS ABDOMINIS AND EXTER NAL...

Страница 30: ...EMENT 22 FACE TRAPEZIUS MUSCLES CERVICAL VERTE BRAE 24 PERIARTHRITIS OF SCAPEL OR HUMERUS 21 GLUTEUS MUSCLES 19 QUADRICEPS 20 INTERNAL THIGH Work position Work position Work position Work position Wor...

Страница 31: ...3 09 04 ELECTRODE PLACEMENT 26 EPICONDYLITIS 25 EPICONDYLITIS 27 CERVICOBRACHIAL NEURALGIA 28 BACK 29 SCIATICA 30 KNEE Work position Work position Work position Work position Work position Work positi...

Страница 32: ...REV 03 09 04 32 Work position Work position Work position Work position Work position Work position 31 32 33 34 35 36 ELECTRODE PLACEMENT for microcurrents...

Страница 33: ...REV 03 09 04 ELECTRODE PLACEMENT for microcurrents Work position Work position Work position Work position Work position Work position 33 37 38 39 40 41 42...

Страница 34: ...ELECTRODE PLACEMENT with accessories Work position Work position Work position Work position Work position Work position 43 44 45 46 47 48 REV 03 09 04 34...

Страница 35: ...ram check that the cables are connected and that the electrodes are positioned on the area to be treated In addition be sure that the electrodes are not worn because this could inhibit their ability t...

Страница 36: ...GLOBUS ITALIA SRL Via Vittorio Veneto 52 31013 TV Tel 0438 7933 Fax 0438 793363 www globusitalia com info globusitalia com...

Отзывы: