76
Motorhome - 02/11-0 - GLO-MJ11-00EN
Electrical system
9
9.6.3
230 V fuse
The 230 V connection is protected by a two-pole automatic circuit breaker
(Fig. 79,1).
Location
The automatic circuit breaker is in the wardrobe or under a cover in the rear
area (under the slatted frame), depending on the model.
Function
Value/colour
Fuses at the
transformer/rectifier
EBL 99
Internal charger module
20 A yellow
Compressor refrigerator/AES refrigerator
20 A yellow
Heater
10 A red
Basic light/entrance step electrical
25 A white
Reserve 4
–
Reserve 3
–
Reserve 2
–
Reserve 1
15 A blue
Solar
15 A blue
Reserve 5
–
Reserve 6
–
Auxiliary charging unit
20 A yellow
Circuit 1
10 A red
Circuit 2
10 A red
TV
10 A red
Water pump
5 A beige
Z
The 230 V automatic circuit breaker is always mounted near the 230 V con-
nection.
Fig. 79
230 V automatic circuit breaker