14 ·
· 15
MANUAL | VA4J&X | VS4C | VA4C | ATEX certified
MANUAL | VA4J&X | VS4C | VA4C | ATEX certified
Problem
Conclusion
Low
speed
Low
Torque
Won’t
run
Runs
well
then
slows
down
x
x
x
There may be dirt or foreign material in the motor.
Inspect and flush the motor.
x
x
x
There may be internal rust in the motor. Inspect and
flush the motor.
x
x
The air pressure may be too low. Increase the air
pressure.
x
x
Incoming airline too narrow. Replace with a bigger
one.
x
x
Limited exhaust. Inspect and repair.
x
x
x
x
Motor is running hot. Perform a service maintenance.
x
x
Inadequate air flow from air source. Inspect and
repair.
x
x
Air source is too far from the motor. Put the air source
closer.
Trouble shooting
Performance
VA4J&X | VS4C | VA4C
»
Silencer supplied with motor.
»
Motor is reversible.
»
Maximum temperature -20°C to +60°C
(-4°F to +140°F).
»
Maximum temperature for non ATEX
applications: -20°C to +80°C (-4°F to
+176°F).
Airsupply lubrication and filtration:
Use 64 micron filtration or better. Choose a
lubricator suitable for the flow required. Prior to
initial startup, inject oil into the inlet port.
Lubricator drop rate 4-5 drop / minute
continuous operations
Lubricator drop rate 9-12 drop / minute
intermittent operation.
Maximum speed 4000 rpm
Life time depends highly on operational speed
and air pressure.
VA4J&X Vane Air Motor
0
1000
2000
3000
4000
1
2
3
4
5
6
7
8
9
7 bar
6 bar
5 bar
4 bar
3 bar
2 bar
SPEED revs per min
TORQUE
Nm
TORQUE - SPEED
0
1000
2000
3000
4000
0,2
0,4
0,6
0,8
1,0
1,2
1,4
1,6
1,8
2,0
2,2
2,4
7 bar
6 bar
5 bar
4 bar
3 bar
2 bar
SPEED revs per min
kW
POWER - SPEED
0
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
9
Minimum
Starting
Torque
Maximum
Starting
Torque
PRESSURE Bar
TORQUE
Nm
TORQUE - PRESSURE
W hen designing for applications where the
minimum start torque requirement is equal to
the running torque (as for example on hoists),
the motor should be operated in the area below
the min starting torque. This will ensure that the
motor will always have adequate starting torque
0
1000
2000
3000
4000
10
20
30
40
50
7 bar
6 bar
5 bar
4 bar
3 bar
2 bar
SPEED revs per min
Free air
l/sec
AIR CONSUMPTION - SPEED
Maximum continuous speed 4000 rpm
AIRLINE FILTRATION AND LUBRICATION
Use 64 micron filtration or better. Choose a lubricator
suitable for the flow required. Prior to initial start-up,
inject oil into the inlet port.
Lubricator drop rate 4-5 drops/minute continuous operation.
Lubricator drop rate 9-12 drops/minute intermittent operation.
Max. Overhung Force on motor shaft 170 N (40 lbf.).
Axial loads should be kept to a minimum.
Attitude: The motor can be operated in all positions.
Maximum temperature -20°C to +80°C (-4°F to +176°F).
Muffler supplied with motor.
Motor is reversible.
A pressure regulator should be used to control the
air pressure to the motor, to limit the maximum
output torque applied to the driven assembly.