background image

APRIL  2019 REV.A

GFS-302

PAGE    4  of  4       

GLOBE

®

 PRODUCT WARRANTY

Globe agrees to repair or replace any of its manufactured 

products found to be defective in material or workmanship 

for a period of one year from date of shipment.
For specific details of our warranty please refer to Price List 

Terms and Conditions of Sale (Our Price List).

ORDERING INFORMATION

SPECIFY:

• 

WRENCH 

 Quantity 

 Part Number

1/2” NPT Standard

 . . . . . . . . . . .  325390

1/2” NPT Recess

.   .   .   .   .   .   .   .   .   .   .   .   325391

 Quantity 

 Part Number

Cap.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   327109-Cap

• 

PROTECTIVE CAPS 

• 

SPRINKLER

 

• 

ESCUTCHEON

 Quantity 

 Finish 

 Part Number  (See TABLE C)

 Quantity 

 SIN 

 Temperature Rating 

 Finish 

 

• 

Part Number (See TABLE B)

TABLE B:  PART NUMBER SELECTION  

PART NUMBER

SIN + TEMPE FINISH

XXXX  XXX  XX

SIN

TEMPERATURE

FINISH

GL3010

3010

155

155°F (68°C)

01

BRONZE

GL4110

4110

175

175°F (79°C)

02

CHROME

GL4910

4910

200

200°F (93°C)

03

WHITE POLYESTER

GL5610

5610

04

BLACK POLYESTER

Note: All combinations may not be available.
          Refer to TABLE A for available listed combinations

1/2" (13mm) ADJUSTABLE RECESSED ESCUTCHEON

FINISH

FRICTION FIT 1/2” NPT

THREADED 1/2” NPT

Chrome

332071

329301

White Polyester

332073-W

329303-W

Brass

332072

NA

Black Polyester

332073-B

NA

TABLE C:  ESCUTCHEONS

Содержание GL-RES Series

Страница 1: ...FPA 13 13D 13R and any other related documents as appropriate The GL3010 is typically utilized when maximum coverag es are not needed thereby reducing flow demands The GL5610 is typically the sprinkler of choice when utilizing Residential Sprinklers within an NFPA 13 Occupancy The larger K factor can be advantageous when needed to con form to the NFPA 13 hydraulic Special Design Approach for Resid...

Страница 2: ...the room or compartment using the area of the room divided by the number of sprinklers in the room 7psi minimum SIN K FACTOR GPM PSI lpm bar TEMPERATURE MAX AREA OF COVERAGE FEET m MINIMUM PRESSURE PSI bar MINIMUM FLOW GPM L min DEFLECTOR TO CEILING MOUNTING SURFACE DISTANCE INCHES mm MINIMUM DISTANCE BETWEEN SPRINKLERS FEET m 155 F 68 C 175 F 79 C 200 F 93 C GL3010 3 0 43 2 cULus EU 1 cULus cULus...

Страница 3: ...e www globesprinkler com Always obtain permission from the proper authorities to shut down the affected fire protection system and notify all personnel who may be affected by this action before closing a fire protection system main control valve for maintenance work on the system that it controls Sprinklers should only be cleaned by means of gently dust ing with a feather duster otherwise non oper...

Страница 4: ...VE CAPS SPRINKLER ESCUTCHEON Quantity Finish Part Number See TABLE C Quantity SIN Temperature Rating Finish Part Number See TABLE B TABLE B PART NUMBER SELECTION PART NUMBER SIN TEMPERATURE FINISH XXXX XXX XX SIN TEMPERATURE FINISH GL3010 3010 155 155 F 68 C 01 BRONZE GL4110 4110 175 175 F 79 C 02 CHROME GL4910 4910 200 200 F 93 C 03 WHITE POLYESTER GL5610 5610 04 BLACK POLYESTER Note All combinat...

Отзывы: